10. SPECIFICATIONS
Frequency
50 kHz
Operating Voltage
7 - 28VDC at the terminal (residual ripple no greater than
100mV)
Power Consumption
500mW @ 24VDC
Analog Output
4 -20mA modulating output module with HART (Recommended
250 Ohm @ 24VDC)
Analog Resolution
14 bits
Communications
4 -20mA with HART
Blanking Distance
250 mm (10")
Maximum Range
8 metres (26’) or 12 metres (40’)
Resolution
1 mm (0.04”)
Electronic Accuracy
+/- 0.25% of maximum range
Operating Temperature
-40°C to 60°C (-40°F to 140°F)
Maximum Operating Pressure
-0.5 to 3 bar (0 - 44 PSI)
Automatic Temperature Compensation
Yes
Beam Angle
Materials
Transducer: PVDF
Housing: Powder coated aluminium
Display
4-line graphic display (128 x 64)
Keypad
4 keys = CAL, RUN, UP, DOWN
Memory
>10 years data retention
Enclosure Sealing
IP67
Cable Entries
M20 cable glands
Mounting
2” BSPT Thread or 2” NPT Thread
Typical Weight
1kg (2.2 pounds)
Volume
Pre-set common vessel shapes
Requires PC connection with Vision System II software
32-point programmable linearization table