14 Field Service Bulletin
HyPro2000 — HT2000 TORCH UPGRADE
Install consumables
Wipe the internal and external surfaces of the
torch with a clean cloth or paper towel.
Apply a thin film of silicone
lubricant on each o-ring.
The o-ring should look shiny, but there should not be any excess or
built-up grease.
1. Install the
electrode
into the
torch head
2. Install the
swirl ring
into the
nozzle
3. Install the nozzle
and
swirl ring into the
nozzle
retaining cap
4. Install the
nozzle
retaining cap
onto the torch
head
5. Install the
shield onto
the nozzle
retaining cap
Install consumables
Check the consumable parts daily for wear before cutting. Before removing consumables, bring the torch to the edge of
the cutting table, with the torch lifter raised to its highest point to prevent the consumables from dropping into the water
of the water table.
Note: Do not overtighten parts! Only tighten until mating parts are seated.
WARNING
Always disconnect power to the power supply before inspecting or changing torch consumable parts. Use gloves
when removing consumables. The torch might be hot.
Tool: 104119

Other manuals for Hypertherm HyPro2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm HyPro2000 and is the answer not in the manual?

Hypertherm HyPro2000 Specifications

General IconGeneral
BrandHypertherm
ModelHyPro2000
CategoryWater System
LanguageEnglish

Related product manuals