Calibration
Calibration can address issues related to the analog sticks and triggers.
1. Set the mode selection switch to USB.
2. Press and hold the SELECT and START buttons while connecting the controller to a PC
using the included USB-C cable.
3. Continue to hold SELECT and START until the LED indicators flash (approximately 4
seconds).
4. Conduct calibration
Rotate the left and right analog sticks three times each and allow to return to
neutral position.
Press and release the left and right triggers and allow to return to neutral position
5. Press Y + D-Pad DOWN to save and exit calibration mode.
Reset
The controller can be manually power cycled by pressing the pin hole button on the rear of the
controller.
Reset