  • J
    John SteinAug 11, 2025
    What to do if my Hypontech Inverter has a Permanent Fault?
    • S
      Shane PhamAug 11, 2025
      If your Hypontech Inverter is showing a Permanent Fault, disconnect it from both the utility grid and the PV array. After the LED turns off, reconnect the inverter. If the fault continues to display, contact the service.
  • P
    perryalexanderOct 24, 2025
    What to do if my Hypontech Inverter shows an Object Error?
    • M
      Mary JamesOct 24, 2025
      If your Hypontech Inverter displays an Object Error, there are several things you can check: * Verify the grounding connection of the inverter is reliable. If the fault persists, contact service. * Inspect the AC cable and grid connection on the inverter. If the fault is still present, contact the service. * Check the grid voltage and grid usability. * Examine the fuse and the triggering of the circuit breaker in the distribution box. * Assess the grid voltage at the point of connection of the inverter. If the grid voltage is outside the permissible range due to local grid conditions, consider modifying the Fault monitored operational limits after informing the electric utility company first. * Check the grid voltage and grid connection on the inverter. * Check the grid freq...

Summary

Safety

2.1 Intended use

Details the proper applications and operating conditions for the HPS inverters.

2.3 Important safety information

Provides critical safety warnings for personnel and supervision of children.

Mounting

4.1 Ambient conditions

Specifies environmental requirements and minimum clearances for inverter installation.

4.3 Mounting the inverter with the wall bracket

Step-by-step instructions for securely mounting the inverter using the provided bracket.

Electrical Connection

5.3 AC connection

Details cable requirements and specifications for connecting the inverter to the AC grid.

5.4 DC Connection

Details the requirements and procedures for connecting the DC input to the inverter.

5.4.2 Assembling the DC connectors

Step-by-step guide for assembling DC connectors, including cable preparation and crimping.

5.4.3 Connecting the PV array

Instructions for safely connecting the PV array to the inverter, including polarity checks.

Communication

Commissioning

7.1 Electrical checks

Lists essential electrical tests for grounding, voltage, polarity, and insulation before commissioning.

7.2 Mechanical checks

Outlines mechanical checks for inverter mounting, cover, and cable gland security.

7.3 Start-Up

Describes the inverter start-up procedure, including indicator lights and operational states.

Disconnecting the Inverter from Voltage Sources

Operation (optional)

Technical Data

Troubleshooting

Maintenance

Hypontech HPS-5000D Specifications

General IconGeneral
ModelHPS-5000D
Rated Power5000 W
Max. DC Power5500 W
Input Voltage360 V
Max. DC Voltage550V
Start Voltage120 V
Number of MPPT Trackers2
Max. Input Current per MPPT11 A
Number of DC Inputs per MPPT1
Max. AC Power5000 W
Output Voltage230 V
AC Voltage Range180-280V
Frequency50/60 Hz
Rated Grid Frequency50/60 Hz
Power Factor>0.99
THDI<3%
DC SwitchYes
Protection DegreeIP65
Cooling MethodNatural Convection
CoolingNatural Convection
CommunicationRS485, Wi-Fi (optional)
Weight15 kg
Protection FeaturesOvervoltage, Overcurrent
Operating Temperature Range-25°C to +60°C
Operating Temperature-25°C to +60°C