Hypro Small Twin
®
Piston
and Plunger Pumps
Form L-1574
Rev. B
Original Instruction Manual
KEEP FOR FUTURE REFERENCE
Series 5315C & 5320C & 5330C & 5324C & 5324C
& 5321C &5322C & 5321C-H & 5322C-H 53702 53703
Small Twin
®
Piston and Plunger Pumps

Questions and Answers

  • E
    esmithAug 3, 2025
    Why is my Hypro 5330C not pumping water?
    • A
      Andrea SerranoAug 3, 2025
      Several factors can cause a Hypro Water Pump to have no flow or low flow. The pump may not be primed, so check for obstructions and leaks in the line. There could be air leaks in the suction line, requiring you to check and reseal the inlet fittings. A blocked or clogged line strainer can also be the culprit; inspect the strainer and clear any debris from the screen. Ensure the suction line is the same diameter as the pump's inlet port or larger, as an undersized or collapsed hose can restrict flow. Also, the nozzle may be clogged, so clear or replace it. Finally, the unloader or relief valve might not be functioning correctly, which would require repair or replacement.
  • J
    jjonesAug 12, 2025
    What to do if my Hypro Water Pump has low pressure?
    • B
      Brandon HuntAug 12, 2025
      If your Hypro Water Pump has low pressure, it could be due to debris in the valves, which requires removing the debris. Another cause could be worn valves, in which case you should replace them. The unloader or relief valve not functioning properly can also cause low pressure; repair or replace the relief valve.
  • C
    collinsstephanieAug 22, 2025
    How to fix a leaking Hypro Water Pump?
    • D
      Dana LarsonAug 23, 2025
      If your Hypro Water Pump is leaking, it could be due to worn seals or a cracked body. Replace the seals, and if the body is cracked, replace it as well.

Summary

Introduction to Hypro Pumps

Prohibited Misuses

Details prohibited uses and conditions that could cause damage or injury.

Pump Technical Data

Assembly and Installation

Installation Procedures

Outlines critical safety and procedural information for pump installation.

Drive Systems and Controls

Belt & Pulley Drive Installation

Details on mounting pulleys, belt tension, and calculating pulley sizes.

Operation and Maintenance

Commissioning, Start-Up, Operation, Shutdown

Procedures and safety precautions for starting, running, and stopping the pump.

Troubleshooting Common Issues

No Flow or Low Flow

Identifies causes and solutions for lack of or reduced pump flow.

Low Pressure

Identifies causes and solutions for reduced pump operating pressure.

Pump Leaking