Parameters 2200 SRM 1286
Table 1. Parameter Default Values
Default RangeParameter
B60Z
AC
and
B60Z
HD
B80Z
AC
and
B80Z
HD
Min Max
Extended Shift OFF OFF ON OFF
Walk Speed (B
oth
Directions)
3.8 3.8 0.5 4.0
Hi Speed Fwd
9.0 9.0 0.5 9.0
Hi Speed Rev
6.0 6.0 0.5 9.0
Minimum Acceleration
5 5 1 10
Maximum Acceleration
7 7 1 10
Plugging
7 7 1 10
ADS-Neutra
l
1 1 1 10
ADS-Throttle
1 1 1 10
Pick Acceleration
6 6 1 10
Pick Deceleration
1 1 1 10
Battery Full Voltage
1
25.300 25.300 24.500 26.500
Lift Interrupt
1
23.520
2
23.520
2
18.000
3
24.000
PS Fwd Trav
3 3 1 10
PS Rev Trav
3 3 1 10
PS Max Assist
5 5 1 10
NOTE: Certain lift truck models are not capable of operating at the Max range allowed by the Dash Display.
If a parameter value higher than the truck’s ability is entered, the value will revert to the maximum allowed
for that lift truck.
1
Values shown in ETACC format. When viewed through the dash display, values will be rounded and
formatted as three digit numbers without decimals. Example: A value of 23.520 in ETACC will appear as
235 in the dash display.
2
Maintenance-free battery option uses value 24.000.
3
This parameter value should not be set below 20 for normal operations. Contact NMHG Service
Engineering Contact Management for approval before operating trucks below this value.
4