2. ACON, PCON
15
8
1
2.4 Wiring Example
2.4.1 Connection Diagram
* Ethernet cable: Straight cable of category 5e or above, 100 m max
(Aluminum tape and braided double-shielded cable are recommended.)
(Note) Terminal processing is not required.
2.4.2 Connector Pin Layout
Pin number Signal name Signal abbreviation
1 Data transmitted + TD+
2 Data transmitted - TD-
3 Data received + RD+
4 Not used
5 Not used
6 Data received - RD-
7 Not used
8 Not used
Connector hood Grounding pin for security FG
RJ45 8-pin
modular connector
(Controller side)
PLC (EtherNet/IP master unit)
Ethernet
cable*
Ethernet cable*
Ethernet cable*
Other slaves
A
CON/PCON
A
CON/PCON
Hub