INSTALLATION AND OPERATION INSTRUCTIONS
1-18
SFT 199 TANKLESS WATER HEATER
1.5.3 Cleaning the Condensate Trap
1. Turn off the power to the water heater and allow it to cool down.
2. Twist the condensate trap cup toward the left and lower the trap cup.
3. Rinse out the trap cup and re ll with water. Inspect the trap, and clean the
interior portion of the trap (attached to the unit).
4. Re-install the condensate trap cup, and twist to the right.
1.5.4 Further Installation Details
Pipe the condensate drain to within 1” of a drain, or connect it to a condensate
pump.
Slope the drainage line down to the drain at a pitch of 1/4” per foot, so that the
condensate runs towards the drain.
Check the condensate traps every 2 months, and clean and re ll as
necessary.
Figure 18: Condensate trap drainage
DANGER
The water in the condensate
neutralizer can cause severe
burns to the skin. Use extreme
caution when servicing the
condensate neutralizer. Wear
protective gloves and eyewear.
CAUTION
When a condensate
neutralization package
is installed, the pH of the
condensate discharge must
be measured on a regular
schedule to ensure the
neutralizing agent is active
and effective.
WARNING
If condensates are to be
discharged into building drain
piping materials that are subject
to corrosion, a neutralization
package must be used.