v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, “Parts listing, Type 8864,” on page 23 to determine which components are customer
replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only)”, that step must be performed only by a
trained service technician.
Error code Description Action
00180700,
00180800
General PCI error.
1. Make sure that no devices have been disabled in
the Configuration/Setup Utility program.
2. Reseat the following components:
a. Failing adapter
Note: If an error LED is lit on the PCI board
or on an adapter, reseat that adapter first; if
no LEDs are lit, reseat each adapter one at a
time, restarting the server each time, to
isolate the failing adapter.
b. (Trained service technician only) PCI board
3.
Replace the components listed in step 2 one at a
time, in the order shown, restarting the server
each time.
00181000 PCI error.
1. Remove the adapters from the PCI slots.
2. Reseat the following components:
a. Failing adapter
Note: If an error LED is lit on the PCI board
or on an adapter, reseat that adapter first; if
no LEDs are lit, reseat each adapter one at a
time, restarting the server each time, to
isolate the failing adapter.
b. (Trained service technician only) PCI board
3.
Replace the components listed in step 2 one at a
time, in the order shown, restarting the server
each time.
01295085 ECC checking hardware test error.
1. Reseat the following components:
a. (Trained service technician only)
Microprocessor
b. DIMM
c. Microprocessor tray
2.
Replace the following components one at a time,
in the order shown, restarting the server each
time.
a. (Trained service technician only)
Microprocessor
b. DIMM
c. (Trained service technician only)
Microprocessor tray
Chapter 5. Diagnostics 83