Power  on  the  system 
To  power  on  the  system,  follow  these  steps: 
1.  DANGER
An
  electrical  outlet  that  is  not  correctly  wired  could  place  hazardous 
voltage  on  metal  parts  of  the  system  or  the  products  that  attach  to  the 
system.  It  is  the  customer’s  responsibility  to  ensure  that  the  outlet  is 
correctly  wired  and  grounded  to  prevent  an  electrical  shock.  (RSFTD201)
Plug  in  the  system  unit  and  system  unit  console  into  an  electrical  outlet.  Plug 
in  everything  you  previously  unplugged  such  as  printers  and  displays. 
2.  Is  your  system  unit  an  iSeries  270,  800,  810  or  820,  825,  830,  840,  870,  890? 
__  270,  800,  or  810:  Continue  with  the  next  step. 
__  820,  825,  830,  840,  870,  890:  Go  to  step  5.
3.
  Look  at  the  Function/Data  display  on  the  control  panel. 
4.  Does  01  B  V=S  appear  in  the  Function/Data  display  with  IPL  mode  Normal 
(OK)  selected? 
__  Yes:  Go  to  step  7  on  page  26. 
__  No:  Do  the  following: 
__  a.  Press  the  Mode  Select  button  until  the  Manual  mode  indicator  (a 
small  hand)  lights  up. 
__  b.  Press  the  Increment/Decrement  push  button  until  02  appears  in 
the  Function/Data  display. 
__  c.  Press  the  Enter  push  button  on  the  control  panel. 
__  d.  Press  the  Increment/Decrement  push  button  until  B  appears  in  the 
Function/Data  display. 
__  e.  Press  the  Enter  push  button  on  the  control  panel. 
__  f.  Press  the  Increment/Decrement  push  button  until  S  appears  in  the 
Function/Data  display 
__  g.  Press  the  Enter  push  button  on  the  control  panel. 
__  h.  Press  the  Mode  Select  button  until  the  Normal  indicator  (OK) 
lights  up. 
__  i.  Press  the  Increment/Decrement  push  button  until  01  appears  in  the 
Function/Data  display. 
__  j.  Press  the  Enter  push  button  on  the  control  panel. 
01  B  S  should  appear  in  the  Function/Display  display.  If  it  does 
not  appear,  repeat  steps  4a  through  4j.  If  it  does,  go  to  7  on  page 
26.
5.
  Look  at  the  Function/Data  display  on  the  control  panel. 
6.  Does  01  B  V=S  appear  in  the  Function/Data  display? 
__  Yes:  Continue  with  the  next  step. 
__  No:  Do  the  following: 
__  a.  Press  the  Increment/Decrement  push  button  until  02  appears  in 
the  Function/Data  display. 
__  b.  Press  the  Enter  push  button  on  the  control  panel. 
 
©  Copyright  IBM  Corp.  2000,  2005  25