IBM 1403 Printer (cont'd)
Th~
program should provide an operator message and exit from this
error
recovery
procedure
when
the
end-of-forms indication
is
detected.
The
operator should
then
perform a forms
runout
(as just described) and satisfy
the
requirements
of
the
appli·
cation program.
5.
Sync
check. This condition can occur whenever
the
print
chain (or train)
is
out
of
synchronism with
the
print
circuitry
in
the
2821. Depending upon
when
the
sync check occurs, one
of
the
following conditions exists:
a.
The
sync check occurred when no printing was
in
progress (no line was
printed).
b.
The
sync check occurred during a print operation and
one
line was
printed.
c.
The
sync check occurred during printing and two lines were printed.
The
program should provide an
operator
message and exit from this error
recovery procedure.
The
operator should
then:
a.
Correct
the
not·ready condition (press
the
Check· Reset key and then
the
Start
key) and allow
the
application program to proceed
without
further
retries of
the
command,
or
b. Correct
the
not·ready condition (press
the
Check Reset key and then
the
Start
key) and restart
the
program from a logical point.
If
the
error
persists, a call should be made
to
the
Customer Engineer.
Data
check
indicates
that
a
code
in
a data record sent
to
the
printer does
not
match a
code
in
the
UCS (Universal Character Set) feature storage. Printing does
not
occur
in
the
print
position
to
which
the
unmatching code applies. The entire line (except for
me
data
cneck
position)
or
only a portion
oT
the
iine may be printed. ThereTore, the
last printed line may contain erroneous data and/or an incomplete record. Data check
generally indicates
that
the
UCS storage was improperly loaded
or
that
a data record
code
(other
than
blank
or
null) does
not
compare
to
any code
in
the
UCS storage.
The
program should provide an
operator
message and exit from this
error
recovery
procedure.
The
operator
should then:
1.
Accept
the
record and indicate
that
the
application program
is
to
proceed
without
further retry
of
the
command,
or
2.
Cause
the
application program
to
restart from a logicat point.
If
the
error
persists, a call should be made
to
the
Customer Engineer.
Parity
Check
This
bit
indicates
that
a parity error has been detected
in
the
UCS
feature storage.
The
parity
d-.eck can
be
reset only
if
the UCS storage
is
raloaded.
If
the
parity check occurs while
the
UCS storage
is
being loaded,
retry
the
operation
once. If
the
error
persists, a call should be made
to
the
Customer Engineer.
If
the
parity
check occurs during printing,
the
last
print
line may contain erroneous
data. Provide an operator message and
exit
from this
error
recovery procedure.
At
this
time,
the
operator
should:
1.
Accept
the
record, cause
the
program
to
reload
the
UCS
storage and proceed
without
further retry
of
the
command,
or
2. Cause
the
program
to
reload
the
UCS storage and restart
the
program at a
logical point.
If
the
error
persists,
..
call should be made
to
the
Customer Engineer.
Page 5-40

Other manuals for IBM System/370

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System/370 and is the answer not in the manual?

IBM System/370 Specifications

General IconGeneral
BrandIBM
ModelSystem/370
CategoryServer
LanguageEnglish

Related product manuals