EasyManua.ls Logo

IBM System x3750 M4 - Physical and Electrical Specifications

IBM System x3750 M4
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
IBM System x3750 M4 26
Physical and electrical specifications
Dimensions and weight:
Width: 446 mm (17.5 in.)
Depth: 734 mm (28.9 in.)
Height: 87 mm (3.4 in.)
Approximate weight, fully configured: 31.1 kg (68.5 lb.)
Supported environment:
Air temperature:
5 - 40 °C (41 - 104 °F) at 0 - 3048 m (10,000 ft); ASHRAE A3 compliant
Humidity: 8% - 80%
Electrical:
100 - 127 (nominal) V AC, 50 Hz or 60 Hz, and System 20 A (10 A per power supply)
200 - 208 (nominal) V AC, 50 Hz or 60 Hz, and System 10 A
200 - 240 (nominal) V AC, 50 Hz or 60 Hz, and System 9 A
Minimum configuration: 0.20 kVA (one power supply)
Minimum configuration: 0.26 kVA (two power supplies)
Typical configuration: 1.12 kVA (two power supplies)
Maximum configuration: 2.16 kVA (two power supplies)
BTU output:
Minimum configuration: 648 BTU/hr (190 watts)
Maximum configuration: 7,336 BTU/hr (2150 watts)
Noise level:
Idle: 6.5 bels
Operating: 6.6 bels

Other manuals for IBM System x3750 M4