SYMPTOM-TO-FRU ERROR MESSAGES
Function-related symptoms
Symptom or error FRU or action, in
sequence
The system does not
suspend or resume when
the LCD is closed or
opened.
1. Go to “Suspend
mode” on page 5,
and check that the
computer can enter
suspend mode.
2. Boot an operating
system and press
Fn+F4. If the
computer enters
suspend mode,
suspect that the
application program is
not working properly.
3. LCD assembly.
4. System board.
The battery Fuel Gauge
does not go higher than
90%.
Go to “Checking the
battery pack” on page 12
and see the note.
The memory count (size)
appears different from the
actual size.
Go to “Testing the
computer” on page 8.
The system hangs
intermittently.
Go to “Intermittent
problems” on page 32.
Indicator-related symptoms
Symptom or error FRU or action, in
sequence
The indicator incorrectly
remains off or on, but the
system runs correctly.
1. Sub card.
2. System board.
The battery power status
indicator blinks from green
to yellow to orange.
1. Check that a correct
battery is installed.
2. Battery pack.
3. System board.
The battery indicator does
not turn on when the battery
is installed.
1. Battery pack.
2. System board.
28 ThinkPad 600X Hardware Maintenence Manual

Table of Contents

Other manuals for IBM ThinkPad 600X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM ThinkPad 600X and is the answer not in the manual?

IBM ThinkPad 600X Specifications

General IconGeneral
BrandIBM
ModelThinkPad 600X
CategoryLaptop
LanguageEnglish

Related product manuals