Questions and Answers

  • L
    Lori KennedyAug 10, 2025
    What to do if my IBO Water Pump fails to launch?
    • B
      Bonnie MitchellAug 10, 2025
      If your IBO Water Pump fails to launch, several factors could be at play. First, check the installation fuse and replace it if it's tripped. Next, ensure the overcurrent circuit breaker is on. If the voltage is too low, verify it matches the supplier's specifications. A blocked pump rotor can also prevent launch, so try unlocking it. If none of these solutions work, the pump may be damaged and require replacement.
  • C
    Christy SanchezAug 15, 2025
    How to fix loud system operation in my IBO Water Pump?
    • B
      Barbara JordanAug 15, 2025
      Loud operation of your IBO Water Pump can often be attributed to air trapped within the installation. To address this, vent the installation to remove any air.
  • R
    Rachel MathewsAug 20, 2025
    What to do if my IBO Water Pump is loud or cannot reach the demand pressure?
    • C
      Carl AndersonAug 20, 2025
      Loud operation or failure to reach demand pressure in your IBO Water Pump can stem from a few causes. One potential cause is low inflow pressure, leading to cavitation; decrease the inflow pressure at the pump inlet. Another reason might be that the pump parameters are too low. If possible, increase the pump operation mode to a more efficient one, or consider installing a stronger pump.
  • B
    Bradley MyersAug 26, 2025
    What causes overcurrent protection in IBO Water Pump?
    • O
      ostewartAug 26, 2025
      Overcurrent protection in your IBO Water Pump is likely due to a short circuit within the internal connection circuit. The suggested solution is to replace the pump.
  • J
    Jamie JohnsonAug 30, 2025
    How to fix locked-rotor protection in IBO Water Pump?
    • T
      Theresa WatsonAug 30, 2025
      Locked-rotor protection in your IBO Water Pump indicates that the rotor is blocked. To resolve this, disassemble the motor and check if the rotor can rotate normally. If it cannot, clean up any impurities to allow the rotor to rotate freely.
  • B
    Billy SmithSep 4, 2025
    What is open phase protection in IBO Water Pump?
    • L
      Lisa WilsonSep 4, 2025
      Open phase protection in your IBO Water Pump is triggered when one or more phases of the internal connection circuit is disconnected. The suggested solution is to replace the pump.

IBO AMG 25-40/180 Specifications

General IconGeneral
Voltage230 V
Frequency50 Hz
PhaseSingle-phase
Inlet/Outlet Size1 1/2 inch
Mounting Length180 mm
TypeCirculator Pump
Maximum Head4 m