9 ICE COBOTICS RS20
OPERATOR MANUAL
BATTERY CHARGING
DRAINING THE RECOVERY TANK
Any time scrubbing is completed, or when relling
solution tank, the recovery tank should be drained
and cleaned.
WARNING: If the recovery tank is not
drained when the solution tank has been
relled, foam or water may enter the oat shut-
o󰀨 screen and cause damage to the vacuum
motor.
1. While holding the Recovery tank drain hose
(machine components, #40) upward, remove
the cap and lower hose to drain.
2. Open the Recovery tank cover (machine
components, #24) and rinse out the tank. Use
a rag to remove any excess dirt.
3. Remove and clean the vacuum fan inlet lter
located in the recovery tank. Clean the lter with
a damp cloth or low pressure water hose if dirty.
Allow the vacuum fan lter to dry completely
before reinstalling it in the machine.
DRAINING THE SOLUTION TANK
Any time scrubbing operation is completed, the
solution tank should be drained and cleaned.
1. Unscrew lter cover (machine assembly #45)
and let clean water tank discharge.
2. Rinse the solution tank with clean water after
every use. This will help prevent chemical
buildup and clogging of the solution lines.
WARNING: Fire Or Explosion Hazard.
Keep Sparks and Open Flame Away. Keep
Battery Compartment Propped Open When
Charging.
Use only ICE COBOTICS supplied or apprved
batteries charger, use unapproved charger may
cause damage to the batteries and machine.
Lithium-ion battery must be stored in a
charged state, please charge monthly.
Batteries charger specications:
Applicable to charging Lithium-ion batteries
Automatic shut o󰀨 circuit
Output current of 15 Amps
Output voltage of 24 volts
1. Transport the machine to a well ventilated area.
2. Turn the machine o󰀨.
3. Please open the sewage tank to maintain
ventilation while charging.
4. Connect the charger's AC power supply cord to
a properly grounded receptable.
5. The charger will automatically begin to charge,
you can watching the charging status on the
window (machine components, #8), once
the charging cycle begins, There are 5 green
indicators on the charger, the LED1 indicator
blinks, indicating that the charging has entered
the rst stage (less than 20%), the LED2
indicator blinks, indicating that the charging has
entered the second stage (20%~40%), the LED3
indicator blinks, indicating that the charging
has entered the third stage (40%~60%), the
LED4 indicator blinks, and the LED1 indicator
blinks. It indicates that the charging enters the
fourth stage (60%~80%), the LED5 indicator
light ashes, indicating that the charging enters
the fth stage (80%~90%), the LED5 indicator
light ashes quickly, indicating that the charging
enters the sixth stage (90%~100%), if the LED
indicator light blinks quickly in turn, it indicates
that the battery is full, unplug the charger,
charging is complete.
NOTE: The machine will can not operate
when charging.
BATTERY USE
WARNING:The machine is only to be used
with the battery provided by manufacturer.
- Against using non-rechargeable batteries.
- The battery must be removed from the
appliance before it is scrapped.
- The machine must be disconnected from
the supply mains when removing the
battery.
- The battery is to be disposed of safely.
- Safely disconnecting at least the non frame
connected pole of the battery or by an
equivalent method (disconnecting device);