Process completion tone. Controls the tones generated at end of
charging or discharging and the cyclic charging/discharging indication.
Options: Beep 5 times, Beep 3 minutes, Beep always (continuous
until user presses STOP), Beep OFF
(Beep always, default)
Back-light and cooling fan control. Adjust the LCD backlight brightness.
There are three cooling fan modes: ON, OFF, AUTO. In AUTO-Mode,
iCharger adjusts the fan automatically to control its internal temperature.
Cooling fan: OFF, ON & AUTO (AUTO, default)
Discharge reduce setting. When you set it to ―ON‖,If the final voltage
target storage voltage is reached, the buzzer will beep for three times,
and the left of the second line display "D>>", and the charger enters into
the high precision discharge process. The process won‘t stop until the
current reaches xx% of the configured discharge current.
Reduce: ON, OFF Range: 1 – 99%
Termination voltage for LiFe. Adjust LiFe‘s charge termination voltage.
Press Start/Enter for more than 3 seconds to blink the ―Voltage‖ value,
then press Dec and Inc to adjust the termination voltage.
Range: 3.40V – 3.90V, Step: 0.01V (3.60V, default)
Termination voltage for Lilo. Adjust Lilo‘s charge termination voltage.
Press Start/Enter for more than 3 seconds to blink the ―Voltage‖ value,
then press Dec and Inc to adjust the termination voltage.
Range: 3.90V – 4.20V, Step: 0.01V (4.10V, default)
Termination voltage for LiPo. Adjust LiPo‘s charge termination voltage.
Press Start/Enter for more than 3 seconds to blink the ―Voltage‖ value,
then press Dec and Inc to adjust the termination voltage.
Range: 4.00V – 4.30V, Step: 0.01V (4.20V, default)
Termination voltage for Pb. Adjust Pb‘s charge termination voltage. Press
Start/Enter for more than 3 seconds to blink the ―Voltage‖ value, then
press Dec and Inc to adjust the termination voltage.
Range: 2.20V – 2.50V, Step: 0.01V (2.40V, default)
Note: The Termination voltage controls the transition from Constant
Current (CC) to Constant Voltage (CV) charging for LiXx and Pb
chemistries. It also defines the per-cell limit for cell overvoltage detection.
If you change the default termination voltage, the charge and discharge
setting screen will note this difference by alternatively blinking battery‘s
type and setting voltage value.