ADJUSTMENT
ADJUSTMENT
CONDITIONS
MEASUREMENT
VALUE
ADJUSTMENT
POINT
BOH
location
UNIT ADJUST
2
*
Reduce 20dB for the input AF signai
level.
Level:
6.5rnV
Freq.:
1kHz
±3,5kHi
PLL
R50
®
IC-3200E
VERSION
Frequency display: 435-OOMHi
TONE: OFF
Apply AF signal to MIC
CONNECTOR,
Level: £0mV
Freq.r 1kHz
Transmit mode
±4.SkHz TX VCO R2
Reduce 2CkJe for the input AF
singal
level.
Level:
2 mV
Freq,:
IkHz
±3.5kHz PLL R50
SUBAUDIBLE
TONE
DEVIATION
®
tC-3200A
VERSIONS
1
Frequency display: 445.00MHz
TONE: ON
TONE No.; OS [08.5Hz)
Apply no signal to MIC
CONNECTOR,
Transmit
mode
ANTENNA
CONNECTOR
Connect a deviation
meter lo
ANTENNA
CONNECTOR
±0.7kHz
PLL
i_ _
R42
®
IC-320OE
VERSION
1
Frequency
display;
435.00MHz
[TONE] SWITCH: Push
Apply no signal to MIC
CONNECTOR,
±3.SkHz
R42
5