Loading...
5 - 5
5-3 SOFTWARE ADJUSTMENT
Select an operation using [] / [] keys, then set specified value using [] / [] keys on the connected computer keyboard.
1
1
2
3
1
2
1
2
1
Operating freq. : 500.000 MHz
Output power : Low1
Connect the RF power meter or 50
dummy load to the antenna connector.
Transmitting
Operating freq. : 450.000 MHz
Output power : High
Transmitting
Output power : Low2
Transmitting
Output power : Low1
Transmitting
Operating freq. : 475.000 MHz
Output power : Low1
IF bandwidth : Wide
Connect an audio generator to the [MIC]
jack through the JIG cable and set as:
1.0 kHz/40 mVrms
Set an FM deviation meter as:
HPF : OFF
LPF : 20 kHz
De-emphasis: OFF
Detector : (PP)/2
Transmitting
IF bandwidth : Narrow
Transmitting
Operating freq. : 475.000 MHz
Set to the DTCS set *channel, and push
[Connect] on the Adjustment software.
*Except bank 1
Output power : Low1
Transmitting
IF bandwidth : Narrow
Transmitting
Operating freq. : 500.000 MHz
Output power : Low1
IF bandwidth : Wide
CTCSS : 67 Hz
DTCS code : 007
Set the FM deviation meter as:
HPF : OFF
LPF : 20 kHz
De-emphasis: OFF
Detector : (PP)/2
No audio applied to the [MIC] connector.
Transmitting
REFERENCE
FREQUENCY
[TXF]
OUTPUT
POWER
[Power (Hi)]
[Power (L2)]
[Power (L1)]
FM
DEVIATION
[MOD W]
[MOD Ratio]
MODULATION
BALANCE
[BAL W]
[BAL Ratio]
CTCSS/DTCS
DEVIATION
[CTCSS/DTCS]
Rear
panel
Rear
panel
Rear
panel
Rear
panel
Rear
panel
Loosely couple a frequency
counter to the antenna connec-
tor.
Connect an RF power meter to
the antenna connector.
Connect an FM deviation meter
to the antenna connector
through the attenuator.
Connect an FM deviation meter
with an oscilloscope to the
antenna connector through an
attenuator.
Connect an FM deviation meter
to the antenna connector
through the attenuator.
500.0000 MHz
25.0 W
5.0 W
1.0 W
±4.1 kHz
±2.1 kHz
±0.7 kHz
ADJUSTMENT ADJUSTMENT CONDITION
MEASUREMENT
VALUE
UNIT
LOCATION