Its Mostly About The Receiver
Starting Point for Receiver settings
13
Not to Scale
Set preamplifier/attenuator so that the noise floor is close to
“S0” on your signal meter
Set RF gain at Max. and AGC speed setting matched to mode:
Fast for CW mode
Medium for Digital modes
Slow for Voice modes (SSB, AM)
Roofing/DSP filter(s) matched to mode, no IF shift:
2.4 - 3.0 KHz for Voice or digital pass-band modes
500 Hz for RTTY
400 - 500 Hz for CW (wider when tuning a split pileup)
Set DSP Noise Reduction levels for modest improvement in
noise level
Leave Noise Blanker off unless you are dealing with a strong
repetitive pulse noise source