5 - 5
+
+
Audio generator
300 Hz to 3 kHz
AC
millivoltmeter
SP+
SP
MICE
MIC
PTT
PTTE
Add a jumper wire here
*OPC-966 (JIG CABLE)
Electrolytic capacity
47 µF
OPC-966
(Cloning cable)
SINAD meter
Speaker (8 )
Audio generator
Connection (common)
to the antenna connector
RF power meter
0.110 W/50
Frequency
counter
Attenuator
40 dB or 50 dB
FM
deviation meter
Standard signal generator
0.1 µV to 32 mV
(127 dBm to 17 dBm)
CAUTION:
DO NOT transmit while
SSG is connected to the
antenna connector.