5 - 9
SOFTWARE ADJUSTMENT – continued
Select an operation using [↑] / [↓] keys, then set specified value using [←] / [→] keys on the connected computer keyboard.
“S-METER (or RSSI L0/L2—[MPT])” adjustment must be performued after “RX SENSITIVITY” adjustment (at page 5-8) is finished.
*The output level of the standard signal generator (SSG) is indicated as the SSG’s open circuit.
Set “SQL level” to
close squelch.
Then set “SQL level”
at the point where
the audio signals
just appears.
1
2
1
• Operating freq. : 400.000 MHz [L]
440.000 MHz [ML]
450.000 MHz [MH]
480.000 MHz [H]
• IF bandwidth : Wide
• Connect an SSG to the antenna con-
nector and set as:
Frequency : 400.000 MHz [L]
440.000 MHz [ML]
450.000 MHz [MH]
480.000 MHz [H]
Level : 14 µV* (–84 dBm)
Modulation : 1 kHz
Deviation : ±3.5 kHz
A
±2.8 kHz B
• Receiving
• Set an SSG as :
Level : 0.45 µV* (–114 dBm)
Modulation : 1 kHz
Deviation : ±3.5 kHz A
±2.8 kHz B
• Receiving
• Operating freq. : 415.000 MHz [L]
460.000 MHz [ML]
470.000 MHz [MH]
496.000 MHz [H1]
500.000 MHz [H2]
• IF bandwidth : Wide
• Connect an SSG to the antenna con-
nector and set as:
Frequency : 415.000 MHz [L]
460.000 MHz [ML]
470.000 MHz [MH]
496.000 MHz [H1]
500.000 MHz [H2]
Level : 0.2 µV* (–121 dBm)
Modulation : 1 kHz
Deviation : ±3.5 kHz
A
±2.8 kHz B
• Receiving
S-METER
[S-METER]
RSSI L0/L2—[MPT]
[RSSI]
SQUELCH
LEVEL
[SQL]
Front
panel
ADJUSTMENT ADJUSTMENT CONDITION
MEASUREMENT
VALUE
UNIT LOCATION
A: W/N version, B: M/N version
Push [ENTER] key on the connected computer keyboard to set
“S3 level (or L2 level—[MPT])”.
Push [ENTER] key on the connected computer keyboard to set
“S1 level (or L0 level—[MPT])”.
Internal speaker