6 - 5
*The output level of the standard signal generator (SSG) is indicated as the SSG’s open circuit.
SOFTWARE ADJUSTMENT (RECEIVING)
• Select an operation using [] / [] keys, then set specified value using [] / [] keys on the connected computer keyboard.
• Need to adjust S-METER ADJUSTMENT after RX SENSITIVITY ADJUSTMENT is adjusted.
Otherwise, S-METER ADJUSTMENT will not be adjusted properly.
Minimum distortion
level
Set SQL level to
close squelch.
Then set SQL level
at the point where
the audio signals
just appears.
1
1
2
1
• Operating CH : CH1
Connect the standard signal generator
to the antenna connector and set as:
Frequency : 400.000 MHz [L]
450.000 MHz [H]
Level : 10 µV* (–87 dBm)
Modulation : 1 kHz
Deviation : ±3.5 kHz
• Receiving
• Operating CH : CH1
Connect the SSG to the antenna con-
nector and set as:
Frequency : 400.000 MHz [L]
450.000 MHz [H]
Level : 14 µV* (–84 dBm)
Modulation : 1 kHz
Deviation : ±3.5 kHz
• Receiving
• Set the SSG as :
Level :
0.45 µV* (–114 dBm)
• Receiving
• Operating CH : CH7
Connect the SSG to the antenna con-
nector and set as:
Frequency : 470.000 MHz [L]
520.000 MHz [H]
Level : 0.2 µV* (–121 dBm)
Modulation : 1 kHz
Deviation : ±3.5 kHz
• Receiving
RX
SENSITIVITY
[BPF T1],
[BPF T2]
S-METER
[S-METER]
SQUELCH
LEVEL
[SQL]
Side
panel
Side
panel
Connect the SINAD meter with
an 8 load to the [SP] jack
through the JIG cable.
Connect speaker to the [SP] jack
through the JIG cable.
ADJUSTMENT ADJUSTMENT CONDITION
MEASUREMENT
VALUE
UNIT LOCATION
CONVENIENT:
The BPF T1, BPF T2 can be adjusted automatically.
q-1: Set the cursor to BPF ALL on the CS-F33G ADJ’s screen and then push [ENTER] key.
q-2: The connected PC tunes BPF T1, BPF T2 to peak levels.
or
w-1: Set the cursor to one of BPF T1, T2 as desired.
w-2: Push [ENTER] key to start tuning.
w-3: Repeat w-1 and w-2 to perform additional BPF tuning.
Push the [ENTER] key on the connected computer’s keyboard
to set L2 level.
Push the [ENTER] key on the connected computer keyboard
to set L0 level.