3. WEIGH MODES
The WEIGH MODE key allows the operator to choose HOLD or FREE mode. When the
auto-draft option is enabled, 3 additional versions of HOLD mode are available. A pointer
on the display shows whether HOLD or FREE is selected. At switch-on, the weighing
mode last used in the previous weighing session is automatically selected.
Hold Mode
HOLD mode should be used for weighing live animals. A press of the WEIGH key starts
an averaging process which then displays the accurate weight of the moving animal. A
new record is added to memory and sent to the printer, if connected. The weight is
locked on the display until the next key press.
Free Mode
FREE mode is suitable for static load weighing and is not intended for the weighing of
live animals. The display is continuously updated with the weight currently on the scale. If
the WEIGH key is used, the averaged weight is briefly displayed, a new record added to
memory and sent to the printer, if connected.
AUTO-DRAFT OPTION
When DRAFT/EID ON-LINE and AUTO-DRAFT = ON are selected in SET-UP, there are
three additional settings available when the WEIGH MODE key is pressed:
Speed Mode
A fast version of the standard HOLD mode with a 1.3 second weigh time. Only for use
with special crates that restrict animal movement, allowing faster weighing. For example,
the Racewell Industries sheep crate and Rite-Weigh portable sheep crate.
High Speed Mode
The fastest version of the standard HOLD mode with a 0.7 second weigh time. Only
suitable for use with special crates that restrict animal movement, allowing faster
weighing. For example, the Racewell Industries sheep crate.
Count Mode
This is a non-weighing mode for use with the Racewell Industries sheep crate. The
animal is held for a fixed amount of time, as set by the operator, then released
automatically from the crate. When changing to this mode, the currently set Count Delay
Time is displayed and may be changed by pressing the key. Next select from
DEFAULT DRAFT = LEFT, CENTRE, RIGHT the fixed gate direction that applies when
operating in Count Mode.
It is recommended that a new Group is selected before using the Count Mode. The
“weight” statistics for this group will then display the number of animals that have been
held and released. When already in the Count Mode, a press of the key allows an
adjustment to the Count Delay Time and a press of the key allows an adjustment of
the Default Draft Direction.
While the Count Delay is in progress, "HOLDING..." is displayed. To extend the hold time
for as long as the operator wishes, press the 0 key (remember 0 for 0verride). When
ready to release the animal, press the ENTER key (or any other key).