■ Auto Operation for Soft Dry(only Heating Model)
• The Setting temperature will be same that of the auto operation for cooling.
- Compressor ON temperature; Setting temperature +2°F
- Compressor OFF temperature; Setting temperture -1°F
■ Auto Operation for Heating(only Heating Model)
- Compressor ON temperature; Setting temperature
- Compressor OFF temperature; Setting temperature
+
6°F
- 16 -
Intake-air temp. below 68°F Over 68°F~below 70°F over 86°F
Setting temp. 68°F Intake air temperature +1°F 86°F
■ Vertical louver auto operation
: In Auto operation mode, when pressing the vertical airflow direction control
button, vertical louver moves as shown below.
MODE0
MODE1
MODE2
MODE3
End
Start
MODE9
(CLOSED)
MODE4
MODE5
MODE6