LIFETIME LIMITED WARRANTY
This meter is warranted to the original purchaser
against defects in material or workmanship. During
the warranty period, IDEAL INDUSTRIES, INC. will,
at its option, replace or repair the defective unit,
subject to verification of the defect or malfunction.
This warranty does not apply to defects resulting
from abuse, neglect, accident, unauthorized repair,
alteration, or unreasonable use of the instrument.
Any implied warranties arising out of the sale of an
IDEAL product, including but not limited to implied
warranties of merchantability and fitness for a par-
ticular purpose, are limited to the above. The manu-
facturer shall not be liable for loss of use of the
instrument or other incidental or consequential
damages, expenses, or economic loss, or for any
claim or claims for such damage, expenses, or eco-
nomic loss.
State laws vary, so the above limitations or exclu-
sions may not apply to you. This warranty gives
you specific legal rights, and you may also have
other rights which vary from state to state.
IDEAL INDUSTRIES, INC.
Sycamore, IL 60178, U.S.A.
800-435-0705 Customer Assistance
www.idealindustries.com
www.testersandmeters.com
ND 1719-2 Made in Taiwan
Ranges
Maintenance
Do not attempt to repair this meter. It contains no
user-serviceable parts. Repair or serving should
only be performed by qualified personnel.
Cleaning
Periodically wipe the case with a dry cloth and
detergent . Do not use abrasives or solvents.
Ranges & Basic Input Overload
Resolution Accuracy Impedance Protection
AC Voltage 200.0/600V 2.5% 10 M OHM
1100 VDC or
peak AC for 1 min
DC Voltage
200.0mV/2.000/20.00 1100 VDC or peak
200.0/600V
2% 10 M OHM
AC for 1 min
Resistance
200.0/2.000k/20.00k
1.5%
—
500VDC or AC
200.0k/2.000M/20.00MΩ rms Electronic
DC Current 2.000m/20.00m/200.0mA 1% 350 mV max
0.5A/250V
Fuse mA input
WARNING: TO AVOID ELECTRIC SHOCK
DISCONNECT MEASURING TERMINALS BEFORE
REMOVING BATTERY COVER.
CAUTION: FOR CONTINUED PROTEC-
TION AGAINST FIRE, REPLACE ONLY WITH FUSE
OF THE SPECIFIED VOLTAGE, CURRENT AND
RUPTURE SPEED RATINGS
Specifications
Display: 3-1/2 digit LCD, 0.625”
numerals, maximum
reading 1999 with
automatic sign.
Overange Indication: “1” most significant
digit displayed
Sampling Rate: 3 times per second
Operating 0° to 50°C
Environment: (32° to 122°F), max RH
80% to 31°C
decreasing linear to
50% RH at 40°C
Storage -20° to 60°C
Environment: (-4° to 140°F) at <80%
relative humidity
Battery Life: 200 hours typical with
zinc carbon
Safety Compliance: IEC 61010-1
Cat II - 600V
Dimensions: 5.6”H x 3.1”W x 1.3”D
(143 x 79 x 33mm)
Weight: Approximately 5.6 oz.
(160g) including battery
Equipment protected by double
insulation.
Instrument complies with overvoltage category II.
Cat II equipment protected from transients in
outlets and long branch equipment. Pollution
degree 2 in accordance with IEC-664. Altitude up
to 2000M. Indoor use.
Diode Testing
Battery & Fuse Replacement