Floor standing, room sealed, condensing boiler with automatic spark ignition and fan assisted combustion.
Installation must be carried out by a Gas Safe Registered Engineer.
Appliance requires 230V, 50Hz supply with 3A fusing, and must be earthed.
Do not operate without casing, avoid storage in compartments, do not tamper with sealed components.
Required clearances for servicing: 20mm above, 5mm sides, 450mm front.
Steps to light the boiler, including switching off electricity and setting controls.
Display codes O (Standby), C (Supply), P (Frost) and LED states during operation.
Boiler controls central heating radiator temperature up to 82°C.
Turn off the mains on/off switch (A) for short periods.
Turn off mains and electricity, drain system for longer periods.
Repeat the procedure detailed in 'To light the boiler'.
Leave heating controls at reduced temp or drain system.
Fault code 'L-A' displayed on overheat; press reset button.
Fault code 'L-F' displayed on flame failure; press reset button.
Identifies controls: A-On/Off switch, B-Thermostat knob, C-Reset, D-LED, E-Display.
Instructions for thawing a frozen condensate pipe using warm water.
Set boiler stat to maximum and heating on continuous during cold weather.
Contact local gas supplier immediately if gas leak is suspected. Do not use naked flame.
Appliance should be serviced annually by a Gas Safe Registered Engineer.
Dust with dry cloth; use damp cloth and mild detergent for marks. Do not use abrasives.
Guide to identify problems external to the boiler before requesting service.