33
- Installation & Servicing
INSTALLATION
42
ADVANCED CONTROL ACCESS CONT'D
Press Display
Factory
Setting
Upper
Limit
Lower
Limit
Description
. - 0 1
. 4 1
. 0 0
. 3 5
N/A 10
Value changes will not influence boiler
N/A 01
Value changes will not influence boiler
. 1 0
. 0 1
. 0 0
Low/Off cycle 00
x0=off
x1=on
Special pump function CH/DHW
0x=CH normal pump function, DHW normal pump function
1x=CH pump off during heat request, DHW normal pump function
2x=CH pump normal function, DHW pump 5 sec on delay after
heat request
3x=CH pump off during heat request, DHW pump 5 sec on delay
after heat request
36
37
38
39
40
41
42
P42
P36
Manual fanspeed (for service use) 00 100 -01
Note -1=off
00 = min fan speed
50 = mid rate
100 = max fan speed
N/A 41
Value changes will not influence boiler
Flow temperature hold (ºC) 01 80 00
Temperature maintained by boiler when no heat request.
Note 0=Off
N/A 35
Value changes will not influence boiler
P37
P38
P39
P40
P41
INSTALLATION