5. OPERATION: __________________________________________________________________________________________________
5.1. System on stand-by
The system goes into “STAND-BY” when the [1] key is pressed until the “0%” light blinks. When this occurs, there is no production in the
electrolysis cell.
Fig. 21
5.2. System configuration
The DOMOTIC Series system can be reconfigured through a menu accessed from the control panel. The system has to be switched off, as
described in point 5.1, in order to access this menu. Once the system has been switched off, press the [1] key for a few seconds until the
system information screen [11] displays “CONF”. To enable selection of each menu option, keep the “SALT TEST” [9] key pressed for
approximately 1 second. Select the desired parameter using the [1] / “” [14] keys and validate by pressing the “SALT TEST” [9] key for
one second again (see Fig. 23). The configuration process enables you to establish the following operative parameters:
MODEL
domotic 12
domotic 24
domotic 32
domotic 42
SOFTWARE VERSION
Shows software version (two digits)
POLARITY SWITCH
Switch every 2 hours
(2)
Switch every 3 hours
Switch every 2 minutes
(1)
OUTPUT LEVEL CONTROL
WHEN CLOSED COVER
(2)
System may be configured to provide an output to cell in the range 10 ... 90% of its nominal
capacity when the pool cover is closed.
COVER CONTROL INPUT ACTIVATION
Deactivated
Activated input when closed
contact
(2)
Activated input when open
contact
ORP/RESIDUAL CHLORINE
CONTROL INPUT ACTIVATION
Deactivated (MANUAL)
(2)
Activated electrolysis system when closed contact (AUTO)
(3)
GAS DETECTOR ACTIVATION
Deactivated
Activated electrolysis system when flooded detector
(2)
EXTERNAL FLOW DETECTOR
(FLOW SWITCH) ACTIVATION
Deactivated
(2)
Activated electrolysis system when closed contact
(1)
WARNING: only use this mode for check tasks, for short periods of time, as it could damage the electrodes. This mode is cancelled when the system is switched off.
(2)
Factory defaults.
(3)
Factory default value in DOM-XX PLUS systems.
Fig. 22

Table of Contents

Other manuals for Idegis DOM-32

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Idegis DOM-32 and is the answer not in the manual?

Idegis DOM-32 Specifications

General IconGeneral
BrandIdegis
ModelDOM-32
CategorySwimming Pool Filter
LanguageEnglish

Related product manuals