10.2 CAUSES AND SOLUTIONS
In the following troubleshooting we listed many of the problems, causes and solutions that can help you to solve the problems that
you might encounter, also directly by the operator.
HIGH PRESSURE PUMP
PROBLEM CAUSE SOLUTION
The pump operates nor-
mally,
but does not reach
the required pressure.
Air intake
Bonded valves
Faulty control valve
Nozzle of wrong size or worn
Piston gaskets worn
Check the suction circuit and check for any formations of
air
Check, clean and replace, if necessary
Check and/or replace if necessary
Replace
Check and/or replace
Uneven pressure Valves worn
Valves blocked
The pump sucks up air
Piston gaskets worn
Check and/or replace
Check and/or clean
Check the suction circuit and check for any formations of
air
Check and/or replace
Drop in pressure after nor-
mal period
of use
Nozzle worn
Valves worn
Valves blocked
Control valve housing worn
Piston gaskets worn
Replace nozzle
Check and/or replace
Check and/or clean
Check and/or replace
Check and/or replace
Pump loud Air present during suction
Suction circuit not suitable,
or delivery valve springs broken
Bearings damaged
High water temperature
Check the suction circuit
Check and/or replace if necessary
Check and/or replace
Reduce water temperature
Water present in the oil Oil retainer damaged
High humidity level in work
environment
Piston gaskets worn
Check and replace
Check and/or replace the oil more frequently
Check and/or replace
Oil leakage from
under the pump
Piston gaskets worn
O-ring seal on piston worn
Check and/or replace
Check and/or replace
Oil leakage Oil retainer damaged Check and/or replace
10  TROUBLESHOOTING