HEATER / FUEL PUMP
PROBLEM CAUSE SOLUTION
The burner
doesn’t start
Fuel level too low
Electrodes damaged
Clogged fuel lter
Clogged fuel nozzle
Ignition transfromer doesn’t spark
Burner motor doesn’t run
Check the fuel level and ll it up
Repair or replace them
Clean or replace it
Clean or replace it
Replace it
Replace it
The pump
does not work
Joint coupling broken. Remove the pump and replace the joint.
Lack of
vacuum
Joint coupling broken.
Blocked pump.
The motor does not run.
The cover are not enough screwed
up.
Suction pipe broken.
There is not enough fuel in the
tank.
Remove the pump and replace the joint.
Remove the pump cover and loosen the 3 screws which
x the gears with a 8-mm hexagonal spanner. Start the
motor and simultaneoulsy tighten the three screws. If the
pump is still blocked is necessary replace it.
Check that the power supply corresponds with that speci-
ed on the nameplate.
Tighten the 4 cover screws with a 4 mm hexagonal span-
ner.
Replace the suction pipe.
Add fuel to the tank.
Unstable
vacuum
Air inltration in suction pipe.
There is not enough fuel in the
tank.
Motor-pump coupling not correct.
Partial block of lters or suction
pipe.
Check that all connections are air-proof.
Add fuel to the tank.
Remove the pump, check if the joint is damaged. If ne-
cessary replace it.
Check the cartridge lter inside the pump by loosen the
screw with 4 mm hexagonal spanner, also check other l-
ter inside the suction pipe.
Noisiness Excessive vacuum.
Air infiltration in suction pipe.
Motor-pump coupling not correct.
Check that the pump sucks fuel.
Check that all connections are air-proof.
Remove the pump, check if the joint is damaged. If neces-
sary replace it.
10  TROUBLESHOOTING
Copyright ©2016 Idrobase Group. All rights reserved.