40
IDS 805 Installer Manual 700-266-02H Issued September 2009
LOC
Description
New
Value
Default
Def.
Data
Pg
0 Reset to Factory Default 0 to Reset 15
1 Zone 1 Type Entry/exit 1 15
2 Zone 2 Type Follower 2 15
3 Zone 3 Type Audible Instant 4 15
4 Zone 4 Type Audible Instant 4 15
5 Zone 5 Type Audible Instant 4 15
6 Zone 6 Type Audible Instant 4 15
7 Zone 7 Type Audible Instant 4 15
8 Zone 8 Type Audible Priority 3 15
System Options
9 Entry/Exit Options See location 9 17
10
Secondary Entry Delay
1 Minute
5
17
11 Tamper per Zone Enable/Disable Disabled 0 18
12 Arming Options See location 1 18
13 Stay Arm Options Stay Mode Enabled 0 19
14 Silent Keypad Panic Options Silent Panic Disabled 0 19
15 Silent Alarm Options Silent Alarm Disabled 0 19
16
Siren Toot on Arm/Disarm
No Toot
0
20
17 Siren Time Out Period 2 Minutes 6 20
18 Exit Delay Period 30 Seconds 3 20
19 AC Fail and Restore Time 2 Minutes 1 21
20 Primary Entry Delay 30 Seconds 3 21
21 Hardware Reset Switch Enable/Disable Enabled 15 21
Out-Put Options
22 Alarm Prog. O/P Pulse Prog. O/P 2 22
23 Audible Priority Prog. O/P Pulse Prog. O/P 1 22
24
Low Battery Prog. O/P
Disabled
0
22
25 Auto Test Prog. O/P Disabled 0 22
26 Duress Prog. O/P Pulse Prog. O/P 1 22
27
AC Fail Prog. O/P
Disabled
0
22
28 Close & Away Prog. O/P Set Prog. O/P 3 High 8 22
29 Open Prog. O/P Set Prog. O/P 3 Low 13 22
30
AC Restore Prog. O/P
Disabled
0
22
31 Cancel Prog O/P Disabled 0 22
32 Fire Prog. O/P Disabled 0 22
33
Medical Prog. O/P
Disabled
0
22
34 Strobe Prog. O/P Disabled 0 22
35 Tamper Prog. O/P Disabled 0 22
36
Silent Priority Prog. O/P
Pulse Prog OP 1
1
22
37 Fire Detect Power Prog. O/P Disabled 0 22
38 Aux. Chime Prog. O/P Disabled 0 22
39 Comms Fail Prog. O/P Disabled 0 22
40 Phone Number 2 Prog. O/P Disabled 0 22
41 D/L Complete Disabled 22
Primary Communication Options
42 Dialling Options Tone 1 24
43 Primary Account Code Digit 1 Disabled 0 26