64
ifm Operating Instructions IO-Link Master with Profinet interface PowerLine 8 Ports IP 65 / IP 67 (AL1202) 2017-06-02
Appendix
>
12.1.5 Outputs
22821
Outputs (digital)
Output function
8; (IO-Link Port Class A: 4 x 1; IO-Link Port Class B: 4 x 1)
Max. current load per output [mA]
200
Short-circuit protection
yes
>
12.1.6 Interfaces
12762
Interfaces
Communication interface
Ethernet; IO-Link
Communication interface
IO-Link; TCP/IP; Profinet IO
Ethernet
Transmission standard
10Base-T; 100Base-TX
Transmission rate
10; 100
Protocol
TCP/IP; Profinet IO
Factory settings
IP address: 0.0.0.0
Subnet mask: 0.0.0.0
Gateway IP address: 0.0.0.0
MAC address: see type label
IO-Link Master
Transmission type
COM 1 / COM 2 / COM 3
IO-Link revision
V1.1
Number of ports class A
4
Number of ports class B
4
>
12.1.7 Operating conditions
22823
Operating conditions
Applications
Indoor use
Ambient temperature [°C]
-25...60
Storage temperature [°C]
-25...85
Max. perm. relative air humidity [%]
90
Max. height above sea level [m]
2000
Protection rating
IP 65; IP 67
Pollution Degree
2