Place the plug of the connecting cable directly in plug-in socket (it is forbidden to connect the device by
means of extension cords or dividers!)
Turn on the main switch Fig.3/2 (p.12), which activates the thermostat, and then aggregate of the device
Set the temperature on thermostat control panel Fig.3/1 (p.12) (thermostat service details on p.16 or 17)
Turn on the lighting switch Fig.3/3 (p.12)
Fig.2 Removing the wooden platform
1 – Unscrew the feet from the platform
2 – Remove the wooden platform
3 – Screw the feet in nuts welded to the frame
of the device
1
2
3
Fig.3 Control panel
1 Thermostat (temperature regulator) panel
(service details in Chapter No. 7 p.16 or 17)
2 – Main switch (turns on/off the aggregate of the device)
3 – Lighting switch
4. EXPLOITATION
Temperature of the cooled space and aggregate operating cycle may uctuate. It depends on numerous factors,
such as amount and temperature of products placed in the device and temperature of the surroundings.
The device should be placed in a dry and well-ventilated place, ensuring proper air exchange (distance between the
wall and the device – min. 10 cm), out of sunlight, kept far from heat sources and devices enforcing air ow (ceiling
and portable ventilators, blow-in heaters). The device functions properly in a room, where temperature falls within
appropriate climatic class stated on the data plate. The operation of the device may worsen when it shall operate in
temperature lower or higher than the stated temperature range.
Remarks and indications
It is necessary to properly level the display cabinet, which will prevent loud operation of the device
andshall ensure proper water (condensate) outow during defrosting.
After transporting the device, wait about 2 hours before its actuation.
The rst lling of cooling space should be performed after its previous cooling to working tempera-
ture. This principle should also be observed after longer pause in exploitation.
Do not block any ventilation holes, which would hamper circulation of the cooled air. It is also neces-
sary to ensure proper airow around the device (aggregate ventilation holes cannot be covered).
Ensure even load on shelves, do not exceed their maximal load and do not exceed maximal lo-
ading.