Water leakage from below the device or into the inside of the chamber:
Check whether the device is properly levelled
Check the patency of outow pipes
Empty the condenser tray or container
Check whether there is not too much ice in the rail and on the condenser – defrost when necessary
The device is operating, but the lighting is off...– Make sure that:
Lighting switch is turned on
Fluorescent lamp or starting switch of the device are not burnt
The device does not reach the proper temperature, the lighting is on...– Make sure that:
Lighting switch is turned on
Temperature setting on the thermostat is properly set
Thermostat works properly
The condenser is clean, if necessary – clean the condenser
Ambient temperature does not exceed 25ºC
Enough time has passed for products to be cooled
Ventilation holes of the device are not blocked
(This concerns the “IGLOO” thermostat) thermostat displays C0 or C1 or C2 instead of displaying temperature:
This situation shall occur, when one of temperature regulation sensors has been destroyed.
The following messages may be displayed in such case:
C0 – temperature sensors inside the chamber are damaged – call authorized service
C1 – failure of evaporator sensor - call authorized service
C2 – failure of condenser alarm sensors (or failure of second evaporator sensor) call authorized service
(This concerns the “IGLOO” thermostat) The device is working, sound signalling is activated...– Make sure that:
The condenser is clean, if necessary clean the condenser
Condenser ventilator is working properly
Ambient temperature does not exceed 25ºC
The device is working too loud...– Make sure that:
The device is standing stably
Furniture adjoining the device do not vibrate when the cooling aggregate compressor is working
Noises made by the operating device are a normal phenomenon. The devices are equipped with ventilators,
engines and compressors, which turn on and off automatically. Each compressor makes certain noises
when operating. These sounds are made by the aggregate engine and by cooling agent owing
through the circuit. This phenomenon constitutes a technical feature of cooling devices and it does
not signify their faulty work.
Steam precipitation on glasses of the device is a normal phenomenon in case of high relative air
humidity exceeding 60% and does not require calling the service!
In the case of environmental conditions exceeding normal levels in accordance with refrigerator
class three (relative humidity above 60%), the phenomenon of water pouring from the system with
automatic condensate evaporation (evaporators) may occur. This is not a malfunction and does
not require a service call.