The instructions below are intended for the skilled technician who will install the cooker,
regulate it and perform technical maintenance and who will ensure that these operations
are carried out in the most correct way possible, in compliance with the regulations in
force.
Important: the cooker must be disconnected from the electric socket before performing
all regulating or maintenance operations.
This appliance complies with the following directives
DIRECTIVE 2002/96/CE
LOW TENSION DIRECTIVE 2014/35/EU
ELECTROMAGNETIC COMPATIBILITY DIRECTIVE 2014/30/EU
REGULATION No. 1935/2004 (contact with foods)
The installation must be done in a workmanlike manner and in full compliance with
the regulations in force concerning electrical installation. Otherwise the manufacturer
declines all responsibility. In this booklet you will also nd the wiring diagram of your
appliance.
The appliances are designed to be connected to the voltage shown on the data plate.
Before connecting the appliance to the mains, make sure that:
The characteristics of the electromagnetic switch or of the socket can withstand the load
of the equipment (see data on the plate);
The power supply system must have an effective earth connection.
The appliance is supplied with a cable (1.2 or 1.8 m) without plug: the connection must
be made taking into account that the yellow-green cable is the earth conductor and must
never be interrupted.
The socket must be visible and reachable so that you can easily disconnect the
appliance.
For direct connection to the network, it is necessary that:
• The limiting valve and the domestic system can bear the load of the equipment (see
serial number plate);
• The power supply system is equipped with an effective ground connection;
• The socket or omni polar switch, with a minimum opening of 3 mm, is easily
accessible once the appliance has been installed;
• A land line disconnect switch is incorporated in accordance with the installation
rules.
The yellow-green earth conductor must never be interrupted even by the switch. The
power supply cable must be positioned so that it does not come into contact with
surfaces that have a temperature higher than 50 ° C above the environment. If it is
necessary to replace the power supply cable, contact the assistance service.
INSTALLATION
Electrical connection
Installation rules
INSTALLATION