6
IMER INTERNATIONAL S.p.A.
KOINE 4/5
THERMAL CUTOUT PROTECTION:
- The electric motors are protected against overload by
the
rmal magnetic cutouts, the activation of which is displayed
by illumination of the red lamp (ref.1h). In this case, after the
PRWRUVKDYHFRROHGWKHVSHFL¿FSHUVRQQHOVKRXOGRSHQWKH
electrical panel and reset the cutouts.
For the mortar pump motor (ref.12) there is an additional
safety protection: a thermal sensor shuts down the machine
in the event of a motor temperature overload.
12. OPERATION
- The hopper safety grille must be ¿WWHG DQG
VHFXUHG
at all times.
Never place materials other than premixed dry materials in
the hopper.
- Opening of the mixing chamber causes shutdown of the
PDFKLQHPRYLQJSDUWV¿J)LUVWFORVHWKHPL[LQJFKDPEHU
and press the start pushbutton to start the machine.
:HDUVSHFL¿HGSURWHFWLYHGHYLFHVEHIRUHZRUNLQJRQ
the machine
FIG.11
FIG.10
Regulate the water to obtain the required consistency.
'LIIHUHQWGLDPHWHUVRIGHÀHFWRUDUHDYDLODEOHPP
WKHVPDOOHUGHÀHFWRUVHQDEOHLPSURYHGQHEXOLVDWLRQDQGWKHODUJHU
ones are more suited to materials with a larger particle size.
)RUVWDQGDUGSODVWHULQJPDWHULDOVWKHGHÀHFWRUZLWKPPKROH
(ref.9b) is used.
However, it is important to measure the distance of the nozzle
(ref.9c) from the outlet so that it is the same as the diameter of
WKHGHÀHFWRU¿J
If no water is delivered, the machine shuts down.
Before restarting the machine, identify the cause of the problem:
YDOYHFORVHGGHOLYHU\KRVHEHQWWDQNHPSW\FORJJHG¿OWHUUHI
Interruptions exceeding 30min should be avoided.