EasyManua.ls Logo

IMER KOINE 4 User Manual

IMER KOINE 4
10 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
PLASTERING MACHINE
Operating,maintenance,spare parts manual
3223425 R18 - 2018/09
KOINE 4/5

Other manuals for IMER KOINE 4

Question and Answer IconNeed help?

Do you have a question about the IMER KOINE 4 and is the answer not in the manual?

IMER KOINE 4 Specifications

General IconGeneral
BrandIMER
ModelKOINE 4
CategoryConstruction Equipment
LanguageEnglish

Summary

Technical Data

Design Standards

Noise Emission Level

Plastering Machine Operation

Plastering Machine Description

Details the components of the plastering machine as shown in Fig. 1.

Operation Safety

Electrical Safety

Mechanical Safety

Transport

Transport Preparation

Prepares the machine for movement by detaching hoses and managing hopper contents.

Lifting Procedures

Details safe methods for lifting the machine using attachment points and suitable equipment.

Disassembly for Transport

Explains how to disassemble the machine for easier transport.

Installation

Connections

Electrical Connection

Details power supply requirements, protection, and connection methods.

Water Connection

Explains how to connect the water hose and ensure adequate water supply.

Air Connection

Details how to connect the air hose to the machine panel and spray jet.

Start-Up

Operation

Operational Safety Checks

Ensures safety by checking safety grille, material type, and wearing protective gear.

Water and Deflector Settings

Guides on regulating water consistency and selecting appropriate deflectors.

Operation Shutdowns and Interruptions

Explains causes of machine shutdowns and advises on operation interruptions.

Machine Shutdown and Cleaning

Shutdown Procedure

Steps to safely stop the machine and depressurize pipelines.

Pipeline Cleaning

Method for cleaning material delivery pipelines using a washing sponge.

Machine Cleaning

Instructions for cleaning the mixer, mixing chamber, and pump components.

Maintenance

Daily Checks

Daily checks for water filter cleanliness.

Weekly Checks

Weekly checks for compressor air filter, mixer, motor connection, and contacts.

Six-Month Inspection

Arrangement for machine inspection by authorized technician.

Repairs

General Repair Precautions

Warnings against starting during repairs and using specialized personnel for electrical work.

Spare Parts

Instructions to use only original IMER spare parts.

Guard Refitting

Ensure safety guards are refitted correctly after repairs.

Silica Dust Warning

Health Risks of Silica Dust

Information on respiratory diseases and cancer risks from crystalline silica inhalation.

Respiratory Precautions

Guidance on using NIOSH-approved respiratory protection and following OSHA regulations.

California Proposition 65

Warning about chemicals in dust known to cause cancer or reproductive harm.

Troubleshooting

Machine Does Not Start

Diagnosing issues when the machine and compressor fail to start.

Machine Does Not Start But Compressor Starts

Troubleshooting electrical or connection issues when only the compressor runs.

Machine Does Not Start (Air Issues)

Checking air supply and nozzle for issues preventing machine start-up.

Machine Does Not Start (Material Issues)

Diagnosing material-related problems in the mixing chamber.

Cell Wheel Does Not Start

Troubleshooting issues with the cell wheel not starting.

Mortar Pump and/or Cell Wheel Does Not Start

Diagnosing electrical or water supply problems for pump/wheel start-up.

Machine Stops After Starting Up

Identifying causes for the machine stopping shortly after startup.

Machine Does Not Stop

Troubleshooting issues where the machine or compressor fails to stop.

Material Flow Stops (Air Bubbles)

Resolving material flow interruptions caused by air bubbles.

Material Flow Stops

Addressing general material flow stoppages, including clogging and worn parts.

Material Delivered to Jet Not Constant

Diagnosing issues with inconsistent material delivery to the jet.

Water Increases in Mixing Chamber During Operation

Checking for solenoid valve faults causing water increase in the mixing chamber.

Indicator Lamps

Blue Indicator Lamp

Indicates correct electric power supply and phase sequence.

Red Indicator Lamp

Signals tripped thermal magnetic cut-outs for motors or pumps.

Green Indicator Lamp

Indicates that there is no water pressure.

White Indicator Lamp

Signals correct operation or safety sensor trips.

Related product manuals