E190601X rev.6_ENG May 30, 2022
WHAT HAPPENED: WHAT TO DO
TEMPERATURE
PROBE FAILURE
A display appears: "ALARM !!! 03 Temperature Probe" (the display temperature
changes to 237°C or 0°C) depending on the type of probe breakage).
The cycle does not stop, but all the heating phases are skipped.
When you tap the touch, the signal is reset.
The breakdown of the temperature probe occurred. Call the Authorized Service
Center.
A display appears: "ALARM !!! 04 Load Timeout".
The machine stops and the buzzer rings for 15 seconds.
When you touch the touch, the alarm is reset and the door opens.
The maximum time to perform a water load has been exceeded. Check that
the loading taps are open, that the load filters are clean and that there are no
water leaks.
If the problem occurs often, call the Authorized Service Center.
A display appears: "ALARM !!! 05 Download Timeout".
The machine stops and the buzzer rings for 15 seconds.
When you touch the touch, the alarm is reset and the door opens.
The maximum time to perform a water discharge has been exceeded. Check
the correct cleaning of the drain line.
If the problem occurs often, call the Authorized Service Center.
If a payment signal exceeds 6 seconds on display appears: "ALARM !!! 06
Token blocked" The alarm remains until the payment system is unlocked.
When the system unlocks, the standard screen returns.
There was an imbalance of the basket during centrifugation.
A rebalancing cycle is started to retry the centrifuge.
Three consecutive imbalances occurred during the same centrifuge: the
centrifuge cycle is abandoned, and the program automatically switches to the
next cycle.
If the problem occurs frequently, make sure of the correct load mode (nominal
capacity, homogeneous load).
A display appears: "ALARM !!! 09 Inverter Block".
There is a problem with the inverter being blocked.
The cycle continues but the basket does not turn when you touch the touch,
the signal is reset.
NOTE: It is possible that the message will be detailed with the type of inverter
block.
Call the Authorized Service Center.
A display appears: "ALARM !!! 11 Warm-up Timeout".
The maximum time to perform a water heating has been exceeded.
The cycle does not stop, but all the heating phases are skipped.
When you tap the touch, the signal is reset.
Call the Authorized Service Center.