SET
Operating instructions
OPERATING DISPLAYA
Indication of system pressure
SET POINTS
press (SET)
Setup-Menu
press (SET) > 4 sec.
System Configuration MENU
+
during power-on procedure
SetpointOUT1
adjust with
confirm with (SET)
R
eset point OUT1
a
djust with
confirm with (SET)
SetpointOUT2
adjust with
confirm with (SET)
Reset point OUT2
adjust with
confirm with (SET)
Set OUT1
select with (SET)
configuration of output 1
Set MODE
select with (SET)
on TIME
select with (SET)
adjust switch on delay with
off TIME
select with (SET)
adjust switch on delay with
END MENÜ
back to Setup-MENU
INFO
s
elect with (SET)
Series and Software-Release No.
Set LIGHT
select with (SET)
Display illumination on/off
Set ZERO
select with (SET)
Zero point suppression
no Code
****
select with (SET)
d
elete with Mastercode 1 and 2
END MENÜ
select with (SET)
back to Operating Display
****
SET
Set OUT2 ***
select with (SET)
configuration of output 2
Set MODE
select with (SET)
Set MODE
select with (SET)
Mastercode 1
SET
Mastercode 2
SET
SET
on TIME
select with (SET)
adjust switch on delay with
off TIME
select with (SET)
adjust switch on delay with
no *
OUT 1/2 Standard Mode
confirm n. o. with (SET)
next step with
nc **
33D is not coded: Menu function „SET
CODE“ can be deleted/activated.
33D is coded: Code can be deleted.
Menu selection and confirmation
of settings
Browsing within menu and
increasing of values
Browsing within menu and re-
ducing of values
END MENU
back to Setup-MENU
Set UNIT
select with (SET)
select (BAR, PSI, MPA) with
Set Filter
select with (SET)
pressure peak damping with
Set CODE
Access protection
determine by pressing 5 buttons of your choice
Clear CODE
select with (SET)
delete access protection
END ME
select with (SET)
back to operating display
OUT 1/2 Standard Mode
confirm n. c. with (SET)
next step with
no *
OUT 1/2 Hysterese Mode
confirm n. o. with (SET)
next step with
nc **
OUT 1/2 Hysterese Mode
confirm n. c. with (SET)
next step with
no *
OUT 1/2 Windows Mode
confirm n. o. with (SET)
next step with
nc **
OUT 1/2 Windows Mode
confirm n. c. with (SET)
next step with
*
no = output signal at atmosphere (0 bar) = 0 V
**
nc = output signal at atmosphere (0 bar) = +U
B
***
Variation 33D for vacuum and with analogue signal 4 to 20 mA (0863042 and 0863046) can be programmed
as follows:
a) 4 to 20 mA adapted to range -1 to +1 bar (0 bar = 12 mA)
b) 4 to 20 mA adapted to range 0 to +1 bar (0 bar = 4 mA)