Event Possible cause Remedy
Actuator doesn’t work
properly
Lack of hydraulic supply Check supply line
Defective main valve Consult valve manufacturer
documentation
Failure of the control
group
Call STI s.r.l. - Customer Care Dept.
Actuator too slow Low supply pressure Adjust supply pressure
Incorrect speed control
settings
Adjust speed controls to increase flow
Wear of the main valve Consult valve manufacturer
documentation
Actuator too fast High supply pressure Reset
Incorrect speed control
settings
Adjust speed controls to decrease flow
Leakages on hydraulic
circuits
Deterioration and/or
damage to gaskets and or
loosed fittings
Tightness loosed fittings
Call STI s.r.l. - Customer Care Dept..
Damage to fittings Call STI s.r.l. - Customer Care Dept.
Leakages on hydraulic
cylinder
Damage to seals Replace cylinder seals
Incorrect position of the
valve
Wrong adjustment of
mechanical stops
Re-adjust setting
Wrong electric limit
switches indication.
Re-adjust setting