Maximum capacity of the contacts 5A(1A) 250VAC
Type of action 1B
Class ErP I (+1%) - 811/2013 (regolazione ON/OFF) - ErP IV (+2%) - 811/2013 (regolazione TPI)
Temperature probe NTC 100KΩ@25°C
Temperature differential on regulation regolazione ON/OFF: 0,5K
Degree of protection IP20
Insulation class Tipo II (doppio isolamento)
Pollution degree 2
Software class A
Heat and re resistance Category D
Storage temperature -25÷60°C
Rated impulse withstand voltage 2,5kV
Installation wall
COMFORT temperature regulation range 10°C÷30°C
REDUCED temperature regulation range 10°C÷26°C
Minimum settable interval 15 minuti
WARNING! It is recommended to install the device in strict accordance with the safety regulations and
laws in force. Before making any connection, make sure that the main switch is off.
INSTALLATION
Install the device away from heat sources and and drafts, about 1.5m from the oor.
Using a screwdriver open the device via the side hooks on the left and then remove the front, separating it from
the base (Fig.2).
Chronomix S - Imit Control System s.r.l. https://manimit.it/en/chronomix-s-2/