10
INSTALLERUSERMAINTENANCE TECHNICIAN
Shutter regulation table
Maior Eolo 24.
Shutter regulation table
Maior Eolo 28.
Shutter regulation table
Maior Eolo 32.
Flue gas shutter notch
Type of installation
(extension of duct in metres)
1 3 4 5 6 10
Ø 60/100 horizontal concentric kit - -
From 0 to
0.5
From 0.5 to
1.5
-
From 1.5 to
3.0
Ø 60/100 vertical concentric kit - -
From 0 to
2.2
From 2.2 to
3.7
-
From 3.7 to
4.7
Ø 80/125 horizontal concentric kit - -
From 0 to
0.5
From 0.5 to
4.6
-
From 4.6 to
7.4
Ø 80/125 vertical concentric kit
From 0 to
5.4
From 5.4 to
9.5
-
From 9.5 to
12.2
Ø 80 vertical separator kit without bends
*From 0
to 20
*From 20
to 40
**From 0
to 22
- -
**From 22
to 32
Ø 80 horizontal separator kit with two bend
*From 0
to 16
*From 16
to 35
**From 0
to 17
- -
**From 17
to 28
Direct intake kit and Ø 80 drain in B
22
conguration - - From 0 to 1 - From 1 to 12 -
* ese maximum extension values are considered intake with 1 metre exhaust pipe.
** ese maximum extension values are considered in draining with 1 metre intake pipe and Ø 44 diaphragm on the intake hole.
Flue gas shutter notch
Type of installation
(extension of duct in metres)
3 4 5 6 10
Ø 60/100 horizontal concentric kit - -
From 0 to
0.5
From 0.5 to
1.5
From 1.5 to
3.0
Ø 60/100 vertical concentric kit - -
From 0 to
2.2
From 2.2 to
3.7
From 3.7 to
4.7
Ø 80/125 horizontal concentric kit - -
From 0 to
0.5
From 0.5 to
4.6
From 4.6 to
7.4
Ø 80/125 vertical concentric kit
From 0 to
5.4
From 5.4 to
9.5
From 9.5 to
12.2
Ø 80 vertical separator kit without bends
*From 0
to 20
*From 20
to 40
**From 0
to 22
-
**From 22
to 32
Ø 80 horizontal separator kit with two bend
*From 0
to 16
*From 16
to 35
**From 0
to 17
-
**From 17
to 28
Direct intake kit and Ø 80 drain in B
22
conguration - From 0 to 1 - From 1 to 12 -
* ese maximum extension values are considered intake with 1 metre exhaust pipe.
** ese maximum extension values are considered in draining with 1 metre intake pipe and Ø 50 diaphragm on the intake hole.
Flue gas shutter notch
Type of installation
(extension of duct in metres)
2 4 7 10
Ø 60/100 horizontal concentric kit -
From 0 to
0.5
From 0.5 to
1.5
From 1.5 to
3.0
Ø 60/100 vertical concentric kit -
From 0 to
2.2
From 2.2 to
3.7
From 3.7 to
4.7
Ø 80/125 horizontal concentric kit -
From 0 to
0.5
From 0.5 to
4.6
From 4.6 to
7.4
Ø 80/125 vertical concentric kit
From 0 to
5.4
From 5.4 to
9.5
From 9.5 to
12.2
Ø 80 vertical separator kit without bends
*From 0
to 20
*From 20
to 40
**From 0
to 22
**From 22
to 32
Ø 80 horizontal separator kit with two bend
*From 0
to 16
*From 16
to 35
**From 0
to 17
**From 17
to 28
Direct intake kit and Ø 80 drain in B
22
conguration From 0 to 1 - From 1 to 12 -
* ese maximum extension values are considered intake with 1 metre exhaust pipe.
** ese maximum extension values are considered in draining with 1 metre intake pipe and Ø 50 diaphragm on the intake hole.
STD.002998/004