33
STV50 ed 09/08 VICTRIX 50 Rev. 002
45 Control type for heating installation
00 = ambient temp. thermostat
01 = external probe
02 = 0-10 V Power
03 = 0-10 V Temperature
00
46 Type of DHW installation
00 = Instantaneous with probe
01 = Instantaneous without probe
02 = Boiler with probe
03 = Boiler without probe
02
47 Manual fan speed
-1 = O
0% 100%
-1
48 PWM signal level for pump 1 4
NOT ENABLED
(32)
49 PWM signal level for pump 10 50
NOT ENABLED
(15)
50 PWM signal level for pump 15 50
NOT ENABLED
(20)
51 PWM hysteresis 1 °C 10 °C
NOT ENABLED
(02)
53 Low/O and pump cycle
x0 = O
x1 = On
0x = Normal heating pump cycle
0x = Normal DHW pump cycle
00
54 Min. rpm for pressure switch (x 100) 5 70 5
55
Min. temperature for boiler maintain
function
0 °C 80 °C 0 °C
56
Ramp up for heating or heating+DHW
function
0 (heating only) 1 (heat+DHW) 0
57 Pre-ignition time NOT ENABLED