EasyManua.ls Logo

Immergas Victrix Tera 32 1 - User Manual

Immergas Victrix Tera 32 1
68 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
VICTRIX TERA
28 1 - 32 1 - 38 1
IE
Instructions and warnings
Installer
User
Maintenance technician
*1.040295ENG*

Table of Contents

Other manuals for Immergas Victrix Tera 32 1

Questions and Answers

  • T
    Tristan JonesAug 7, 2025
    How to deal with the smell of gas from Immergas Victrix Tera 32 1?
    • S
      Samantha RobbinsAug 7, 2025
      If you smell gas from your Immergas Boiler, it's likely due to a leakage from the gas circuit pipelines. Immediately check the sealing efficiency of the gas intake circuit to resolve this issue.
  • R
    richard96Aug 12, 2025
    What to do if Immergas Boiler safety thermostat activates frequently?
    • A
      Anthony RodriguezAug 12, 2025
      If your Immergas Boiler frequently activates the safety thermostat, it could be due to several reasons: 1. **Lack of water:** Ensure the system pressure is within the established limits by checking the pressure gauge. 2. **Poor water circulation:** Verify that the radiator valves are open to allow proper water flow. 3. **Blocked pump:** Check the functionality of the pump to ensure it's circulating water effectively.
  • C
    Claudia LiuAug 17, 2025
    Why does my Immergas Victrix Tera 32 1 Boiler have repeated ignition blocks?
    • K
      Katrina CarterAug 17, 2025
      Repeated ignition blocks in your Immergas Boiler can stem from a couple of issues: * **No gas supply:** Confirm there's pressure in the network and that the gas adduction cock is open. * **Incorrect gas cock adjustment:** Ensure the gas valve is correctly calibrated.
  • H
    hutchinsonericAug 21, 2025
    How to fix irregular combustion or noisiness in Immergas Victrix Tera 32 1 Boiler?
    • T
      Taylor SmithAug 22, 2025
      Irregular combustion or noisiness in your Immergas Boiler can be attributed to: * A dirty burner. Clean the burner and ensure correct installation of the terminal. * Incorrect combustion parameters. Check the correct setting of the gas valve (Off-Set setting) and the correct percentage of CO2 in the flue gas. * Intake-exhaust terminal not correctly installed. Clean the components and ensure correct installation of the terminal.
  • P
    Paul JacksonAug 27, 2025
    How to stop noise due to air in Immergas Victrix Tera 32 1 system?
    • A
      Ashley HallAug 27, 2025
      If you notice noise due to air in the Immergas Boiler system: * Check the opening of the special air vent valve cap. * Make sure the system pressure and expansion vessel pre-charge values are within the set limits; The factory-set pressure values of the expansion vessel must be 1.0 bar, the value of system pressure must be between 1 and 1.2 bar.
  • S
    Shannon VaughnSep 1, 2025
    What causes a blocked siphon in Immergas Boiler?
    • H
      Herbert ClaytonSep 1, 2025
      A blocked siphon in your Immergas Boiler might be due to dirt or combustion products deposited inside. To resolve this, check, by means of the condensate drain cap, that there are no residues of material blocking the flow of condensate.

Summary

Instructions and Warnings

Installer Section

Information specific to the installation professional.

User Section

Guidance for the end-user.

Maintenance Technician Section

Procedures for maintenance personnel.

General Warnings

Installer Warnings

Safety and compliance advice for installers.

User Warnings

Safety and usage advice for users.

Maintenance Technician Warnings

Safety and procedural advice for technicians.

Boiler Installation

Installation Recommendations

Guidelines and requirements for boiler placement.

Installation Standards

Risk of Damage Due to Corrosion

Filling the Condensate Drain Trap

Procedure for ensuring correct condensate trap filling.

Main Dimensions

Minimum Installation Distances

Required clearances for safe boiler installation.

Antifreeze Protection

Installation Inside the Recessed Frame (Optional)

Hydraulic Connection

Electrical Connection

Installation with System Operating at Direct Low Temperature

Adapting the boiler for low-temperature systems.

Remote Controls and Room Chrono-Thermostats (Optional)

External Temperature Probe (Optional)

Immergas Flue Systems

Resistance Factors and Equivalent Lengths

Data on flue system component resistance.

Positioning the Gaskets

Correct placement of flue system gaskets.

Coupling Extension Pipes and Concentric Elbows

Connecting flue system extensions and elbows.

Installation Inside the Recessed Frame

Flue installation within a recessed frame.

Outdoor Installation in Partially Protected Area

Cover Kit Assembly

Instructions for assembling the protective cover kit.

Internal Installation Using a Recessed Frame with Direct Air Intake

Configuration Type B, Open Chamber and Fan Assisted

Direct air intake installation in recessed frames.

Max. Length of Exhaust Pipe

Maximum allowable length for exhaust pipes.

Concentric Horizontal Kit Installation

Concentric Vertical Kit Installation

Separator Kit Installation

Adaptor C9 Kit Installation

Technical Data

Variable Heat Output

Boiler heat output specifications.

Ducting of Flues or Technical Slots

Configuration Type B, Open Chamber and Fan Assisted for Indoors

Flue Exhaust to Flue;Chimney

Flues, Chimneys, Chimney Pots and Terminals

Water Treatment System Filling

Instructions for Use and Maintenance

Cleaning and Maintenance

Control Panel

Using the Boiler

Fault and Anomaly Signals

Information Menu

Instructions for Maintenance and Initial Check

General Warnings

Safety precautions before maintenance or initial setup.

Initial Check

Steps for commissioning the boiler after installation.

Yearly Appliance Check and Maintenance

Wiring Diagram

Possible Problems and Their Causes

Converting the Boiler to Other Types of Gas

Calibration of Fan Speed

Calibration of the CO₂ at Minimum Output

Adjusting fan speed for optimal CO₂ at low output.

Calibration of the CO₂ at Maximum Output

Adjusting fan speed for optimal CO₂ at high output.

Adjustment of the Air-Gas Ratio

Programming the P.C.B.

Programming Phase Sequence

Step-by-step guide to PCB programming.

Password-Protected Special Functions

Automatic Vent Function (dL)

Screed Heater Function

Flue Installation (FU)

Maintenance Function (MA)

Chimney Sweep Function

Solar Panels Coupling Function

Pump Anti-Block Function

3-Way Anti-Block System

Radiators Antifreeze Function

Casing Removal

Combustion Parameters

Technical Parameters for Combination Boilers

Product Fiche (in Compliance with Regulation 811;2013)

Parameters for Filling in the Package Fiche

Parameters for Filling in the Assembly Chart

Parameters for Filling in the DHW Package Fiche

Immergas Victrix Tera 32 1 Specifications

General IconGeneral
TypeCondensing Boiler
Power Output32 kW
Fuel TypeNatural Gas / LPG
Energy Efficiency Class HeatingA
Energy Efficiency Class DHWA
Water Pressure0.5 - 3 bar
Max Working Temperature85°C
IgnitionElectronic
Noise Level49 dB