58
4.5 TECHNICAL PARAMETERS FOR COMBINATION BOILERS IN COMPLIANCE WITH REGULATION 813/2013.
Eciencies in the following tables refer to the gross caloric value.
Model/s: Victrix Tera 28 1
Condensing Boilers: YES
Low temperature boiler: NO
Boiler type B1: NO
Co-generation appliance for central heating: NO Fitted with supplementary heating system: NO
Mixed heating appliance: YES
Element Symbol Value Unit Element Symbol Value Unit
Nominal heat output P
n
24 kW
Seasonal energy eciency of central
heating
η
s
93 %
For heating only boilers and combination boilers: useful heat output For central heating only and combination boilers: eective eciency
At nominal heat output in high temper-
ature mode (*)
P
4
24.0 kW
At nominal heat output in high temper-
ature mode (*)
η
4
88.1 %
At 30% of nominal heat output in a low
temperature mode (**)
P
1
8.0 kW
At 30% of nominal heat output in a low
temperature mode (**)
η
1
97.6 %
Auxiliary electricity consumption Other items
At full load el
max
0.010 kW Heat loss in standby P
stby
0.057 kW
At partial load el
min
0.005 kW Ignition burner energy consumption P
ign
0.000 kW
In standby mode P
SB
0.002 kW Emissions of nitrogen oxides NO
X
35
mg /
kWh
For combination central heating appliances
Stated load prole XL
Domestic hot water production e-
ciency
η
WH
87 %
Daily electrical power consumption Q
elec
0.122 kWh Daily gas consumption Q
fuel
22.406 kWh
Contact information IMMERGAS S.p.A. VIA CISA LIGURE, 95 - 42041 BRESCELLO (RE) ITALY
(*) High temperature mode means 60°C on return and 80°C on ow.
(**) Low temperature mode for condensation Boilers means 30°C , for low temperature boilers 37°C and for other appliances 50°C of return
temperature.
Model/s: Victrix Tera 32 1
Condensing Boilers: YES
Low temperature boiler: NO
Boiler type B1: NO
Co-generation appliance for central heating: NO Fitted with supplementary heating system: NO
Mixed heating appliance: YES
Element Symbol Value Unit Element Symbol Value Unit
Nominal heat output P
n
28 kW
Seasonal energy eciency of central
heating
η
s
93 %
For heating only boilers and combination boilers: useful heat output For central heating only and combination boilers: eective eciency
At nominal heat output in high temper-
ature mode (*)
P
4
28.0 kW
At nominal heat output in high temper-
ature mode (*)
η
4
87.85 %
At 30% of nominal heat output in a low
temperature mode (**)
P
1
9.3 kW
At 30% of nominal heat output in a low
temperature mode (**)
η
1
97.58 %
Auxiliary electricity consumption Other items
At full load el
max
0.012 kW Heat loss in standby P
stby
0.0573 kW
At partial load el
min
0.006 kW Ignition burner energy consumption P
ign
0.000 kW
In standby mode P
SB
0.002 kW Emissions of nitrogen oxides NO
X
30
mg /
kWh
For combination central heating appliances
Stated load prole XL
Domestic hot water production e-
ciency
η
WH
87 %
Daily electrical power consumption Q
elec
0.131 kWh Daily gas consumption Q
fuel
22.362 kWh
Contact information IMMERGAS S.p.A. VIA CISA LIGURE, 95 - 42041 BRESCELLO (RE) ITALY
(*) High temperature mode means 60°C on return and 80°C on ow.
(**) Low temperature mode for condensation Boilers means 30°C , for low temperature boilers 37°C and for other appliances 50°C of return
temperature.

Table of Contents

Other manuals for Immergas Victrix Tera 32 1

Related product manuals