Instructions and recommendations
Installer
User
Maintenance technician
*1.047821ENG*
*1.047821ENG*
IE
VICTRIX TERA
V2 2435 PLUS EU

Table of Contents

Questions and Answers

  • H
    hunter96Aug 17, 2025
    How to detect gas leak from Immergas VICTRIX TERA V2 24 PLUS EU?
    • B
      Beth OdomAug 18, 2025
      If you smell gas, it may be caused by leakage from gas circuit pipelines. Check the sealing efficiency of the gas intake circuit.
  • G
    Gabriela BanksAug 20, 2025
    Why is my Immergas VICTRIX TERA V2 24 PLUS EU making abnormal noises?
    • D
      David VegaAug 20, 2025
      Abnormal noises in the system may be due to air. Ensure the system pressure is between 1 and 1.2 bar, and the expansion tank factory-set pressure is at 1.0 bar. Also, check the opening of the special air vent valve cap.
  • L
    Lindsey JonesAug 23, 2025
    What to do if my Immergas Boiler has repeated ignition blocks?
    • J
      Justin MathewsAug 23, 2025
      Repeated ignition blocks can occur due to several reasons. Check the presence of pressure in the network and ensure the gas adduction valve is open. Also, make sure that the condensate drain is functioning correctly and that the condensate has not affected combustion components, the fan, or the gas valve. Check the function of the condensate sensor.
  • J
    John AndrewsAug 26, 2025
    Why is my Immergas VICTRIX TERA V2 24 PLUS EU Boiler combustion irregular or noisy?
    • B
      bbrownAug 26, 2025
      Irregular combustion or noisiness can be caused by a dirty burner, clogged primary heat exchanger, incorrect combustion parameters, or an incorrectly installed intake-exhaust terminal. Check these components to resolve the issue.
  • B
    brett81Aug 27, 2025
    How to fix abnormal noises in the condensation module of my Immergas VICTRIX TERA V2 24 PLUS EU?
    • E
      Elizabeth MorrowAug 27, 2025
      Abnormal noises in the condensation module may be due to air. Remove any air inside the condensation module using the manual air vent valve. When finished, close the manual air vent valve.
  • J
    Joshua RuizAug 30, 2025
    How to stop gas smell from Immergas VICTRIX TERA V2 24 PLUS EU?
    • B
      Brandy RichardAug 30, 2025
      If you smell gas from your Immergas Boiler, it's likely due to a leak in the gas circuit pipelines. You should check the sealing efficiency of the gas intake circuit to resolve this issue.
  • M
    Michael EnglishSep 1, 2025
    What to do if Immergas VICTRIX TERA V2 24 PLUS EU Boiler overheating safety device trips frequently?
    • H
      Hector AndersonSep 2, 2025
      If your Immergas Boiler frequently trips the overheating safety device thermostat, it could be due to several reasons: lack of water in the appliance, poor water circulation, or a blocked pump. Check that the system pressure is within established limits on the pressure gauge. Also, ensure the radiator valves are open and the pump is functioning correctly.
  • K
    Kyle SalazarSep 4, 2025
    What causes repeated ignition blocks in Immergas VICTRIX TERA V2 24 PLUS EU?
    • N
      nicole29Sep 4, 2025
      Repeated ignition blocks in your Immergas Boiler can be caused by a lack of gas or a clogged condensate drain. Check that there is pressure in the network and that the gas adduction cock is open. Restore or release the function of the condensate drain, ensuring the condensate hasn't affected combustion components, the fan, or the gas valve. Also, check the function of the condensate sensor.
  • A
    Austin LaneSep 7, 2025
    How to fix irregular combustion in Immergas Boiler?
    • C
      Christina DaySep 7, 2025
      If your Immergas Boiler has irregular combustion or is making excessive noise, it could be due to a dirty burner, a clogged primary heat exchanger, incorrect combustion parameters, or an improperly installed intake-exhaust terminal. Check these components to identify and resolve the issue.
  • J
    joshua21Sep 9, 2025
    Why does my Immergas Boiler condensation module make abnormal noises?
    • J
      James PayneSep 9, 2025
      If you hear abnormal noises in the condensation module of your Immergas Boiler, it's likely due to air in the module. Use the manual air vent valve to eliminate any air present. Remember to close the manual vent valve once you've finished.

Summary

UNIT INSTALLATION

INSTALLATION WARNINGS

Critical warnings for appliance installation and user safety.

MAIN DIMENSIONS

Detailed physical dimensions and connection points of the appliance.

MINIMUM INSTALLATION DISTANCES

Specifies required clearances around the appliance for safe operation.

ANTIFREEZE PROTECTION

Guidance on protecting the appliance and system from freezing.

INSTALLATION INSIDE THE RECESSED FRAME (OPTIONAL)

Instructions for installing the boiler within an optional recessed frame.

APPLIANCE CONNECTION UNIT

Details on the connection unit for hydraulic and gas system hookups.

GAS CONNECTION

Procedures and safety precautions for connecting the gas supply.

HYDRAULIC CONNECTION

Instructions for connecting the appliance to the heating and hot water systems.

ELECTRICAL CONNECTION

Steps and safety guidelines for the appliance's electrical hookup.

REMOTE CONTROLS AND ROOM CHRONO-THERMOSTATS (OPTIONAL)

Information on installing and using optional remote controls and thermostats.

EXTERNAL TEMPERATURE PROBE (OPTIONAL)

Details on connecting an optional external probe for temperature regulation.

GENERAL EXAMPLES OF TYPES OF INSTALLATION OF FLUE SYSTEMS

Illustrations and descriptions of various approved flue system configurations.

IMMERGAS FLUE SYSTEMS

Information on Immergas approved flue systems and their installation requirements.

MAXIMUM FLUE LENGTH

Specifies the maximum permissible flue lengths for different configurations.

CONFIGURATION FOR C6 FLUE INSTALLATION

Technical data and installation notes for the C6 flue configuration.

OUTDOOR INSTALLATION IN PARTIALLY PROTECTED AREA

Guidelines for installing the appliance in partially protected outdoor locations.

INTERNAL INSTALLATION USING A RECESSED FRAME WITH DIRECT AIR INTAKE

Steps for installing the appliance in a recessed frame with direct air intake.

CONCENTRIC HORIZONTAL KIT INSTALLATION

Instructions for installing horizontal concentric flue kits.

CONCENTRIC VERTICAL KIT INSTALLATION

Instructions for installing vertical concentric flue kits with aluminium slate.

SEPARATOR KIT INSTALLATION

Assembly instructions for the Ø 80/80 separator kit.

C9 ADAPTOR KIT INSTALLATION

Instructions for installing the C9 adaptor kit for specific configurations.

CONCENTRIC KIT C10 CONFIGURATION (Ø 80;125)

Details on the C10 concentric kit configuration and its requirements.

CONFIGURATION C10 - C12 SEPARATOR KIT (Ø 80;80)

Information on C10-C12 separator kit installation.

DUCTING OF FLUES OR TECHNICAL SLOTS

Explanation of ducting operations for flue systems.

FLUE EXHAUST TO FLUE;CHIMNEY.

How to connect flue exhaust to flues or chimneys.

WATER TREATMENT PLANT FILLING

Recommendations for treating system water to prevent damage and ensure efficiency.

SYSTEM FILLING

Procedure for filling the heating system with water.

APPLIANCE START-UP (IGNITION)

Step-by-step guide for safely starting up and commissioning the appliance.

CIRCULATION PUMP

Explanation of the variable speed circulator pump and its operating modes.

MAIN COMPONENTS

Diagram and key identifying the main internal components of the appliance.

INSTRUCTIONS FOR USE AND MAINTENANCE

GENERAL RECOMMENDATIONS

General safety precautions and operational advice for users.

CLEANING AND MAINTENANCE

Guidance on annual cleaning and maintenance to ensure optimal performance.

CONTROL PANEL

Detailed explanation of the appliance's control panel buttons and indicators.

USING THE APPLIANCE

Instructions on how to operate the appliance in different modes (Summer, Winter).

FAULT AND ANOMALY SIGNALS

Table detailing error codes, causes, and solutions for appliance malfunctions.

INFORMATION MENU

How to access and navigate the information menu to view operating parameters.

APPLIANCE SWITCH-OFF

Steps to safely switch off the appliance.

RESTORE CENTRAL HEATING SYSTEM PRESSURE

Procedure for checking and restoring central heating system pressure.

DRAINING THE SYSTEM

Instructions on how to drain the boiler and system.

ANTIFREEZE PROTECTION

Information on the appliance's antifreeze function and system protection.

PROLONGED INACTIVITY

Recommendations for shutting down the appliance during prolonged periods of inactivity.

CLEANING THE CASE

How to clean the appliance casing.

PERMANENT SHUTDOWN

Procedures for permanent shutdown and disconnection.

INSTRUCTIONS FOR MAINTENANCE AND INITIAL CHECK

GENERAL RECOMMENDATIONS

Safety precautions and requirements before performing maintenance.

INITIAL CHECK

Checklist for commissioning the appliance to ensure correct setup and safety.

YEARLY APPLIANCE CHECK AND MAINTENANCE

Detailed annual checks and maintenance tasks for safety and efficiency.

HYDRAULIC DIAGRAM

Diagram illustrating the hydraulic circuit of the appliance.

WIRING DIAGRAM

Diagram showing the electrical connections and components.

TROUBLESHOOTING

Common troubles, possible causes, and solutions for appliance issues.

CONVERTING THE APPLIANCE TO OTHER TYPES OF GAS

Steps and precautions for converting the appliance to different gas types.

FAN SPEED CALIBRATION

Procedures for calibrating fan speed based on flue configuration and gas type.

CO2;O2 REGULATION

Steps for adjusting CO2/O2 levels for optimal combustion.

P.C.B. PROGRAMMING

Guide to accessing and modifying appliance parameters via the PCB.

PASSWORD-PROTECTED SPECIAL FUNCTIONS

How to access special functions using a password for advanced settings.

SCREED HEATER

Instructions for activating and using the screed heater function for floor heating systems.

MAINTENANCE FUNCTION (MA)

How to activate the maintenance function to test operating devices without full startup.

CHIMNEY SWEEP

How to activate the chimney sweep function for combustion parameter checks.

CASING REMOVAL

Step-by-step guide for removing the appliance casing for maintenance.

REPLACING THE MANIFOLD INSULATING PANEL

Detailed steps for replacing the manifold insulating panel.

ASSEMBLY OF MANIFOLD GASKET ON CONDENSATION MODULE

Procedure for assembling the manifold gasket onto the condensation module.

TECHNICAL DATA

VARIABLE HEAT OUTPUT

Table showing heat output, fan speeds, and gas flow rates for different operating conditions.

COMBUSTION PARAMETERS

Data on CO2, O2, CO, NOx, and flue temperatures for calibration.

TECHNICAL DATA TABLE

A comprehensive table of technical specifications for the appliance models.

KEY FOR DATA NAMEPLATE

Explanation of the labels and codes found on the appliance's data plate.

TECHNICAL PARAMETERS FOR COMBINATION BOILERS (IN COMPLIANCE WITH REGULATION 813;2013)

Technical parameters and efficiencies as per EU regulation for combination boilers.

PRODUCT FICHE (IN COMPLIANCE WITH REGULATION 811;2013)

Product fiche detailing energy efficiency ratings and consumption.

PARAMETERS FOR FILLING IN THE PACKAGE FICHE

Guidance on filling out package fiche documentation for heating systems.

Immergas VICTRIX TERA V2 24 PLUS EU Specifications

General IconGeneral
BrandImmergas
ModelVICTRIX TERA V2 24 PLUS EU
CategoryBoiler
LanguageEnglish

Related product manuals