110
INSTALLER
USERMAINTENANCE TECHNICIAN
TECHNICAL DATA
3.24 ASSEMBLING THE MANIFOLD ON THE CONDENSATION MODULE
1. Place the manifold (2, Fig. 79 or Fig. 80) on the module (3, Fig. 79 or Fig. 80).
2. Tighten the 4 nuts (1, Fig. 79 or Fig. 80) on the condensation module (3, Fig. 79 or Fig. 80) in the sequence (A, B, C, D of Fig. 79 or Fig. 80)
shown in the drawing.
e tightening torque when assembling the manifold (2) on the condensation module (3) must be 4 Nm.
Do not exceed 5 Nm.
Victrix Tera V2 24 Plus EU
A
D
C
B
1
2
3
1
79
Victrix Tera V2 35 Plus EU
1
2
3
1
A
C
D
B
80