Model/s: Victrix Tera 38 1
Condensing Boilers: YES
Low temperature boiler: NO
Boiler type B1: NO
Co-generation appliance for central heating: NO Fitted with supplementary heating system: NO
Mixed heating appliance: YES
Element Symbol Value Unit Element Symbol Value Unit
Nominal heat output P
n
32 kW
Seasonal energy eciency of central
heating
η
s
93 %
For heating only boilers and combination boilers: useful heat output For central heating only and combination boilers: eective eciency
At nominal heat output in high temper-
ature mode (*)
P
4
32.0 kW
At nominal heat output in high temper-
ature mode (*)
η
4
88.1 %
At 30% of nominal heat output in a low
temperature mode (**)
P
1
10.6 kW
At 30% of nominal heat output in a low
temperature mode (**)
η
1
97.7 %
Auxiliary electricity consumption Other items
At full load el
max
0.042 kW Heat loss in standby P
stby
0.055 kW
At partial load el
min
0.007 kW Ignition burner energy consumption P
ign
0.000 kW
In standby mode P
SB
0.002 kW Emissions of nitrogen oxides NO
X
34
mg /
kWh
For combination central heating appliances
Stated load prole XL
Domestic hot water production e-
ciency
η
WH
85 %
Daily electrical power consumption Q
elec
0.124 kWh Daily gas consumption Q
fuel
23.108 kWh
Contact information IMMERGAS S.p.A. VIA CISA LIGURE, 95 - 42041 BRESCELLO (RE) ITALY