is appliance can be installed outdoors in a partially protected area.
By partially protected area, we mean one in which the unit is not directly exposed to the elements (rain, snow, hail, etc.).
Installation of gas appliances, ue exhaust pipes and combustion air intake pipes is forbidden
in places with a re risk (for example: garages, closed parking stalls), and in potentially dan-
gerous places.
Do not install on the vertical projection of hobs.
Do not install in places/rooms that constitute public areas of apartment buildings, internal
stairways or other escape routes (e.g. oor landings, entrance halls, etc.).
Installation is also forbidden in places/rooms that constitute public areas of apartment build-
ings such as cellars, entrance halls, attics, los, etc., unless otherwise provided for by local
regulations in force.
ese appliances, if not adequately isolated, are not suitable for installation on walls of com-
bustible material.
Wall mounting of the appliance must guarantee stable and ecient support for the generator.
e plugs (standard supply) that come with the appliance are only to be used to x the latter to the wall; they only ensure adequate support
if inserted correctly (according to technical standards) in walls made of solid or semi-hollow brick or block. In the case of walls made
from hollow brick or block, partitions with limited static properties, or in any case walls other than those indicated, a static test must be
carried out to ensure adequate mount.
ese appliances are used to heat water to below boiling temperature in atmospheric pressure.
ey must be connected to a central heating system and domestic hot water circuit suited to their performance and capacity.
Risk of damage due to corrosion caused by unsuitable combustion air and environment.
Spray, solvents, chlorine-based detergents, paints, glue, ammonium compounds, powders and similar cause product and ue
duct corrosion.
Check that combustion air power supply is free from chlorine, sulphur, powders, etc.
Make sure that no chemical substances are stored in the place of installation.
If you want to install the product in beauty salons, paint workshops, carpenter’s shop, cleaning companies or similar, choose a
separate installation area that ensures combustion air supply that is free from chemical substances.