TB 15-18
16 TB15-18_00_03-2012
ENGLISH
Off-SET vALUE
The OFF-SET value refers to the difference between the temperature inside the cooling compartment and
the temperature set and presented on the display.
It is possible to set three different OFF-SET levels dependent on the temperature set on the display. The
recommended OFF-SET value is 2°C, in order to achieve a temperature within the cooling compartment
which corresponds with the temperatures presented on the display.
Note: we do not recommend modifying the preset OFF-SET values.
• Withtemperaturesgreater than -6°C, set the value
to OF1 which will provide a maximum difference of
2°C between the compartment temperature and the
temperature on the display
• Withtemperaturesbetween -7°C and -12°C, set the
value to OF2 which will provide a maximum difference
of 4°C between the compartment temperature and the
temperature on the display
• With temperaturesinferior to -13°C, set the value
to OF3 which will provide a maximum difference of
4°C between the compartment temperature and the
temperature on the display